Anritsu MA2473A

10 MHz - 18 GHz Gamma di Frequenza
-70 dBm a +20 dBm Gamma di Potenza
Diodo rilevatore a risposta rapida Tipo di Rilevatore
2,92 mm (K-type), femmina Connettore RF
50 Ohm Impedenza
Richiedi scheda tecnica
Attributo Valore
Gamma di Frequenza 10 MHz - 18 GHz
Gamma di Potenza -70 dBm a +20 dBm
Tipo di Rilevatore Diodo rilevatore a risposta rapida
Connettore RF 2,92 mm (K-type), femmina
Impedenza 50 Ohm
Incertezza di Calibrazione ±1,1% (a 50 MHz, 0 dBm, 25°C)
Coefficiente di Riflessione (SWR) ≤ 1,15 (10 MHz - 2 GHz)
Temperatura Operativa 0°C a +55°C
Compatibilità Compatibile con misuratori di potenza Anritsu serie ML2430A e ML2480B
Fattore di Calibrazione Memorizzato internamente tramite EEPROM
Anritsu MA2473A Options:
  • MA2473A - MA2473D - Standard Diode Sensor, 10 MHz to 32 GHz, K(m) connector
  • ML2490A - 06 - Rear Mount Input A
  • ML2490A - 07 - Rear Input A and Reference
  • ML2490A - 08 - Rear Mount Inputs A, B and Reference
  • ML2490A - 09 - Rear Mount Inputs A and B
  • ML2490A - 33 - Extra Operating Manual
  • ML2490A - 34 - Extra Programming Manual
  • ML2490A - 37 - Electronic Manuals (deletes paper version from shipment)
  • ML2490A - 98 - Calibration to Z540, ISO Guide 25
  • ML2490A - 99 - Premium Calibration
  • ML2480A - 06 - Rear Mount Input A
  • ML2480A - 07 - Rear Input A and Reference
  • ML2480A - 08 - Rear Mount Inputs A, B and Reference
  • ML2480A - 09 - Rear Mount Inputs A and B
  • ML2480A - 15 - Factory Fitted 50MHz and 1GHz Calibrator (required by MA2411B Sensor)
  • ML2480A - 15R - Retro Fit Calibrator Kit
  • ML2480A - 33 - Extra Operating Manual ML2487/8A
  • ML2480A - 34 - Extra Programming Manual ML2487/8A
  • ML2480A - 35 - Extra Operating Manual: Japanese
  • ML2480A - 36 - Extra Programming Manual: Japanese
  • ML2480A - 37 - Electronic Manuals only (deletes paper version from shipment)
  • ML2480A - 98 - Calibration to Z540, ISO Guide 25
  • ML2480A - 99 - Premium Calibration
  • ML2400A - 32A - Maintenance Manual ML2480/90A Series
  • ML2400A - 31A - Option 31, Extra Operation/Prog manual ML2480A
  • ML2400A - 10585-00003 - Maintenance Manual ML2400A Series
  • ML2400A - 33 - Extra Operating & Programming Manual ML2437/8A
  • MA2499B - MA2499B - Anritsu 4700 & 4600 Series Sensor Adapter
  • ML2400A - 06 - Rear Mount Input A on ML2437A
  • ML2400A - 07 - Rear Input A and Reference on ML2437A
  • ML2400A - 08 - Rear Mount Inputs A, B and Reference
  • ML2400A - 09 - Rear Mount Inputs A and B on ML2438A
  • ML2400A - 11 - NiMH Battery with Desktop Charger
  • ML2400A - 11A - NiMH Battery with Desktop Charger (for use in Japan only)
  • ML2400A - 22 - 3m Sensor Cable
  • ML2400A - 23 - 5m Sensor Cable
  • ML2400A - 24 - 10m Sensor Cable
  • ML2400A - 25 - 30m Sensor Cable
  • ML2400A - 26 - 50m Sensor Cable
  • ML2400A - 27 - 100m Sensor Cable
  • ML2400A - 30 - Extra Operation Manual ML2437/8A
  • ML2400A - 98 - Calibration to Z540, ISO Guide 25
  • ML2400A - 99 - Premium Calibration
  • ML2400A - 30A - Option 30, Extra Operation/Prog manual (For use in Japan, only)
  • MA2473A - 760-209 - Hardside Transit Case
  • MA2473A - D41310 - Soft Carry Case with Shoulder Strap
  • MA2473A - MA2418A - 50 MHz Reference Oscillator with Power Supply
  • MA2473A - ML2400A-01 - Rack Mount, single unit
  • MA2473A - ML2400A-03 - Rack Mount, side by side
  • MA2473A - ML2400A-05 - Front Bail Handle
  • MA2473A - ML2400A-12 - Front Panel Cover
  • MA2473A - ML2400A-20 - Spare 1.5m Sensor Cable
  • MA2473A - ML2400A-21 - 0.3m Sensor Cable
  • MA2473A - ML2400A-28 - RS232 Bootload Cable
  • MA2473A - ML2400A-29 - Bulkhead Adapter
  • MA2473A - ML2419A - Range Calibrator
  • MA2473A - MA2497A - Agilent/HP84xxA Series Sensor Adaptor
Modulo di calibrazione Anritsu MA2473A

Modulo di riparazione Anritsu MA2473A
Maximum file size: 40MB

No Related Posts

Ulteriori informazioni
ModelMA2473A

L’Anritsu MA2473A è progettato per diagnosi RF ad alta frequenza, coprendo da 10 MHz a 32 GHz con un’eccezionale gamma dinamica da –70 dBm a +20 dBm (~90 dB). Offre prestazioni a banda larga, logica di misurazione a diodi rapida e costanti di calibrazione memorizzate in EEPROM per una precisione costante.

Ideale per test aerospaziali, telecomunicazioni e applicazioni RF avanzate, l’Anritsu MA2473A supporta segnali CW e impulsivi, garantendo affidabilità in ambienti impegnativi.

Testwall può fornire l’Anritsu MA2473A usato, completamente testato. Con supporto esperto e consegna globale, Testwall garantisce strumenti ad alte prestazioni con affidabilità e qualità del servizio senza pari. Contattaci direttamente se hai bisogno di calibrazione o riparazione dell’Anritsu MA2473A.

Clicky Copyright © 2013-present Magento, Inc. All rights reserved.