Anritsu MG3695C

| Attributo | Valore |
|---|---|
| Gamma di frequenza | Da 2 kHz a 67 GHz |
| Potenza di uscita massima | +20 dBm (tipica) |
| Potenza di uscita minima | -110 dBm |
| Purezza spettrale (rumore di fase) | -116 dBc/Hz a 10 kHz di offset (tipico a 10 GHz) |
| Risoluzione di frequenza | 0,001 Hz |
| Modulazioni supportate | AM, FM, ΦM, Impulso, modulazione I/Q |
| Connettore di uscita RF | 2,4 mm (femmina) |
| Interfacce di controllo | GPIB, USB, LAN (Ethernet) |
| Alimentazione | 100–240 V CA, 50/60 Hz |
| Dimensioni (L × A × P) | 426 mm × 222 mm × 570 mm |
Anritsu MG3695C Options:
- MG3695C - 1A - Rack Mount with slides. Rack mount kit containing a set of track slides, mounting ears, and front panel handles to let the instrument be mounted in a standard 19-inch equipment rack.
- MG3695C - 1B - Rack Mount without slides. Modifies rack mounting hardware to install unit in a console that has mounting shelves. Includes mounting ears and front panel handles.
- MG3695C - 2C - Mechanical Step Attenuator. Adds a 10 dB/step attenuator. Rated RF output power is reduced.
- MG3695C - 3 - Ultra Low Phase Noise. Adds new modules to significantly reduce SSB phase noise. Not available with Option 3X.
- MG3695C - 3X - Premium Phase Noise. Improves Option 3 < 1 kHz offset. Not available with Option 3.
- MG3695C - 4 - 8 MHz to 2.2 GHz RF coverage, Ultra-Low Phase Noise version. Uses a digital down converter to significantly reduce SSB phase noise. All specifications apply ≥ 10 MHz.
- MG3695C - 5 - 8 MHz to 2 GHz RF Coverage. Uses an analog down converter. All specifications apply ≥ 10 MHz.
- MG3695C - 6 - Analog Sweep Capability. When used with Option 4, analog sweep capability is limited to ≥ 500 MHz.
- MG3695C - 9V - Rear Panel Output. Moves the RF output connector to the rear panel.
- MG3695C - 9K - Rear Panel Output. Moves the RF output connector to the rear panel.
- MG3695C - 10 - User-Defined Modulation Waveform Software. External software package provides the ability to download user-defined waveforms into the memory of the internal waveform generator, serially or via GPIB or Ethernet. External PC and an instrument with LF Generator, Option 27, are required.
- MG3695C - 12 - Frequency and Phase Modulation. External, via a rear panel BNC connector. For internal modulation capability, requires addition of an LF Generator, Option 27.
- MG3695C - 14 - Amplitude Modulation. External, via a rear panel BNC connector. For internal modulation capability, requires addition of an LF Generator, Option 27.
- MG3695C - 15C - High Power. Adds high-power RF components to the instrument to increase its output power level.
- MG3695C - 16 - High Stability Time Base. Adds an ovenized, 10 MHz crystal oscillator as a high-stability time base.
- MG3695C - 17 - Delete Front Panel. Deletes the front panel for use in remote control applications where a front panel display and keyboard control are not needed. Only available with Options 1A or 1B.
- MG3695C - 22 - 0.1 Hz to 10 MHz Audio coverage. Uses a DDS for coverage down to approximately DC. When adding Option 22, the output power is derated by 2 dB. Frequency resolution below 10 MHz is 0.02 Hz. No modulation is available in the 0.1 Hz to 10 MHz band. Not available without Option 4 or 5.
- MG3695C - 26A - Pulse Modulation. External, via a rear panel BNC connector. For internal modulation capability, requires addition of a Pulse Generator, Option 27.
- MG3695C - 26B - Pulse Modulation. External, via a rear panel BNC connector. For internal modulation capability, requires addition of a Pulse Generator, Option 27.
- MG3695C - 27 - Internal LF and Pulse Generators. Provides modulation waveforms for internal AM (if Option 14 installed), FM (if Option 12 installed), ΦM (if Option 12 installed) and Pulse (if Option 26A/B installed). Not available without Option 12, 14, or 26.
- MG3695C - 28B - Analog Modulation Suite. Bundles Options 12, 14, 26 and 27, offering internally- and externally-driven AM, FM, ΦM, and Pulse Modulation.
- MG3695C - 36 - Ultra-Stable Phase Tracking. Provides the capability for ultra-stable phase tracking between instruments using the internal 100 MHz reference. Requires Option 3 or 3X.
- MG3695C - CE - CE Compliance with CE mark.
- MG3695C - 98 - Standard Calibration to ISO17025 and ANSI/NCSL Z540-1. Provides a calibration certificate, decal, and "Calibration void if removed" tamper seals.
- MG3695C - 99 - Premium Calibration to ISO17025 and ANSI/NCSL Z540-1. Provides everything included with Option 98 plus test report and uncertainty data.
| Model | MG3695C |
|---|
Il generatore di segnali RF/Microonde Anritsu MG3695C offre una copertura eccezionale da 2 GHz a 50 GHz (estensibile a 70 GHz con moltiplicatori) tramite un’unica uscita coassiale, garantendo rumore di fase SSB di –119 dBc/Hz (tipico a 10 GHz, offset di 10 kHz), elevate velocità di commutazione e un set completo di modulazioni analogiche tra cui AM, FM, fase e impulso, per le applicazioni di simulazione di segnali più complesse.
Progettato per comunicazioni wireless, aerospaziale, difesa e test elettronici, questo generatore altamente configurabile supporta l’emulazione di radar a impulsi stretti e fornisce segnali di clock puliti grazie alle opzioni di basso rumore di fase e base tempi ad alta stabilità. L’interfaccia intuitiva e il controllo remoto tramite GPIB o Ethernet offrono la massima flessibilità.
Testwall può fornire l’Anritsu MG3695C usato, completamente testato. Con supporto esperto e consegna globale, Testwall garantisce strumenti ad alte prestazioni con affidabilità e qualità di servizio senza pari. Contattaci direttamente se hai bisogno di calibrazione o riparazione dell’Anritsu MG3695C.