Boonton

Boonton RTP5318

Real-Time Peak Power Sensor, 50 MHz to 18 GHz, -34 to +20 dBm
50 MHz – 18 GHz Intervallo di Frequenza
-35 dBm a +20 dBm Intervallo di Potenza
SMA (femmina) Connettore RF
50 Ohm Impedenza
100 ns (tipico) Tempo di Risposta
Richiedi scheda tecnica
Attributo Valore
Intervallo di Frequenza 50 MHz – 18 GHz
Intervallo di Potenza -35 dBm a +20 dBm
Connettore RF SMA (femmina)
Impedenza 50 Ohm
Tempo di Risposta 100 ns (tipico)
Interfaccia di Comunicazione USB
Tensione di Alimentazione Alimentato tramite USB (5 V)
Tipo di Rilevatore Sensore di potenza RF a diodo, risposta a picco in tempo reale
Temperatura Operativa 0 °C – 55 °C
Dimensioni Compatto, formato palmare
Boonton RTP5318 Options:
  • RTP5318 - ACAL0 - 17025 Accredited Calibration for RTP5318
  • RTP5318 - CAL1 - Prepaid Z540 Calibration for RTP5318
  • RTP5318 - ACAL1 - Prepaid 17025 Accredited Calibration for RTP5318
  • RTP5318 - CARE1 - Prepaid Z540 Calibration and Repair for RTP5318
Modulo di calibrazione Boonton RTP5318

Modulo di riparazione Boonton RTP5318
Maximum file size: 40MB

No Related Posts

Ulteriori informazioni
ModelRTP5318

 BOONTON RTP5318 Real-Time Peak Power Sensor  

 

The Boonton RTP5318 Real-Time Peak Power Sensors are the performance leaders in RF and microwave peak power measurement. They offer industry-leading performance with the widest video bandwidth, fastest rise times, finest time resolution, narrowest minimum pulse widths, highest pulse repetition rates, and superior measurement reading rates. In addition, the RTP5318 sensors incorporate Boonton's unique Real-Time Power Processing technology.  The RTP5318 features 100 ps time base resolution and with an acquisition rate up to 100 MSPS, can provide 50 points per division with a time base range as low as 5 ns / division.

With superior performance and a small form factor, the Boonton RTP5318 is ideal for many purposes ranging from design and verification, through manufacturing, to field installation and maintenance. The sensors are trusted by engineers and technicians at industry-leadering companies to measure pulsed, bursted, and/or modulated signals used in commercial and military radar, electronic warfare (EW), wireless communications (e.g., LTE, LTE-A, and 5G), and consumer electronics (WLAN), as well as education and research applications. To simplify test, the RTP5318 can measure and calculate 16 common power and timing parameters and display the parameters of interest, including rise time, fall time, pulse average, overshoot, and droop.  

 

Specifications for the  BOONTON RTP5318 Real-Time Peak Power Sensor Include:

Frequency Range 50 MHz to 18 GHz
Dynamic Range (avg) -34 to +20 dBm
Rise time (fast/std) 5 ns / < 10 µs
Video Bandwidth (high/std) 70 MHz / 350 kHz

 

Clicky Copyright © 2013-present Magento, Inc. All rights reserved.