Chroma

Chroma 19057-20

DC Hipot Analyser, 20kV
0 - 20 V Tensione di uscita
0 - 5 A Corrente di uscita
100 W Potenza massima
1 canale Numero di canali
USB, GPIB, RS-232 Interfaccia di comunicazione
Richiedi scheda tecnica
Attributo Valore
Tensione di uscita 0 - 20 V
Corrente di uscita 0 - 5 A
Potenza massima 100 W
Numero di canali 1 canale
Interfaccia di comunicazione USB, GPIB, RS-232
Risoluzione della tensione 1 mV
Risoluzione della corrente 0,1 mA
Precisione della tensione ±0,05% + 10 mV
Precisione della corrente ±0,1% + 5 mA
Alimentazione richiesta 100 - 240 V CA, 50/60 Hz
Chroma 19057-20 Options:
  • 19057-20 - A190355 - 19" rack mounting kit
  • 19057-20 - A190356 - GPIB interface
  • 19057-20 - A190519 - HV contact check box
  • 19057-20 - A190702 - 40kV high voltage testing rod
  • 19057-20 - A190708 - ARC (Flashover) verification fixture
Modulo di calibrazione Chroma 19057-20

Modulo di riparazione Chroma 19057-20
Maximum file size: 40MB

No Related Posts

Ulteriori informazioni
Model19057-20
 Chroma 19057-20 DC Hipot Analyser  The Chroma 19057-20 Hipot Analyser is specifically designed for testing and analyzing ultra-high withstand voltage. This model includes 20 kVdc with maximum 10mA output capable of performing AC/DC withstand voltage and insulation resistance tests as well as contact check for production line testing. In addition to the patented Open Short Check (OSC), High Voltage Contact Check is added to test the components with high insulation capability for high voltage output to improve the testing reliability and efficiency. The Hipot Analyser mainly provides high withstand voltage test and analysis for optical couplers, HV relays, HV switches, and PV modules components, which have better insulation capability.Charge and discharge are required for capacitive components when conducting the DC withstand voltage test. The Chroma 19057-20 Hipot Analysers have fast charging functions that can increase the production test efficiency. The unit includes a Flashover (ARC) detection function allowing discharge level analysis through the start voltage, end voltage, and number of steps and time. Discharge Level Analysis (DLA) mode provides detection of Flashover (ARC) and Breakdown (high limit). In addition, external Oscilloscopes can be used with the unit to check the waveform at the same time during analysis. Analysis of the test results the 19057-20 Hipot Analyser provides allows R&D engineers the knowledge to increase quality and performance of insulation components. Specifications for the Chroma 19057 DC Hipot Analyser Include:      