Chroma

Chroma 61812

Regenerative Grid Simulator, 12 kVA
1800 VA Potenza Massima
0 - 300 V CA Tensione di Uscita
45 Hz - 500 Hz Frequenza di Uscita
9 A (a 200 V) Corrente di Uscita Massima
≤ 0,5% Distorsione Armonica Totale (THD)
Richiedi scheda tecnica
Attributo Valore
Potenza Massima 1800 VA
Tensione di Uscita 0 - 300 V CA
Frequenza di Uscita 45 Hz - 500 Hz
Corrente di Uscita Massima 9 A (a 200 V)
Distorsione Armonica Totale (THD) ≤ 0,5%
Interfacce di Comunicazione GPIB, RS-232, USB
Forma d'Onda di Uscita Sinusoidale
Tensione di Ingresso 180 V - 250 V CA, 50/60 Hz
Display LCD retroilluminato
Dimensioni (L x A x P) 430 mm x 133 mm x 500 mm
Chroma 61812 Options:
  • 61812 - A618001 - Softpanel for 61800 Series
  • 61812 - A620039 - GPIB remote interface (option)
  • 61812 - A620045 - CAN remote interface (option)
Modulo di calibrazione Chroma 61812

Modulo di riparazione Chroma 61812
Maximum file size: 40MB

No Related Posts

Ulteriori informazioni
Model61812

 CHROMA 61812 Regenerative Grid Simulator

 

The Chroma 61812 regenerative grid simulators have a power rating of 12kVA, and includes single phase and 3-phase operation.  With output voltage ranges up to 350VLN and 606VLL, each model can achieve 700VLN by a single phase 3-wire setup.  The total harmonic distortion rate is less than 0.5% at full load and 50Hz/60Hz output frequency. In addition to AC output, a DC output mode and AC plus DC output mode is included which can be expanded to DC test and AC test with DC bias voltage. The cur output capability can provide 3 times the RMS peak current, which is suitable for a DUT input inrush cur test.  

Chroma 61812 units are regenerative providing a complete energysaving solution. The power generated by the DUT during the test can be easily fed back to the grid, rather than dissipated as heat, which protects the environment and lowers the cost of operation.  For regulatory testing, 61812 grid simulators can be applied to IEC 61000-3-2/-3- 3/-3-11/-3-12, IEEE 1547/IEC 62116, electric vehicle to grid (V2G) testing, electric vehicle to load (V2L) testing, electric vehicle to home (V2H) testing, energy storage system (ESS) testing.  Remote interfaces include standard USB, LAN, and optional GPIB, CAN interface. Instruments can be controlled by computer and Chroma Softpanel software for fast digital operation.

 

Specifications for the  CHROMA 61812 Regenerative Grid Simulator Include:

Max Power (AC) 12kVA (4kVA per phase)
AC Voltage Range 0~350VLN / 0~606VLL
Max Power (DC) 12kW (4kW per phase)
DC Max Voltage 495V

 

 