Fluke

Fluke 1594A

Calibration Super-Thermometer, 0.8 ppm
-200 °C a 962 °C Gamma di temperatura
0,0001 °C Risoluzione della temperatura
±0,005 °C Incertezza di misura
4 canali di ingresso per termometri a resistenza (PRT/SPRT) Numero di canali
PRT, SPRT, termistori e sensori a 4 fili Tipo di sensori supportati
Richiedi scheda tecnica
Attributo Valore
Gamma di temperatura -200 °C a 962 °C
Risoluzione della temperatura 0,0001 °C
Incertezza di misura ±0,005 °C
Numero di canali 4 canali di ingresso per termometri a resistenza (PRT/SPRT)
Tipo di sensori supportati PRT, SPRT, termistori e sensori a 4 fili
Scala di temperatura ITS-90
Corrente di eccitazione Selezionabile: 1 mA, 2 mA
Interfacce di comunicazione RS-232, IEEE-488 (GPIB), USB
Display Display LCD retroilluminato ad alta risoluzione
Alimentazione 100 V - 240 V CA, 50/60 Hz
Fluke 1594A Options:
  • 1594A - CAL-1594A - Recal With As-Found Data
  • 1594A - 1994 - Verification, Extended Range, 100-500 k Ohms, 1594A
Modulo di calibrazione Fluke 1594A

Modulo di riparazione Fluke 1594A
Maximum file size: 40MB

No Related Posts

Ulteriori informazioni
Model1594A

 FLUKE  1594A Calibration Super-Thermometer  

 

The Fluke Calibration 1954A Super-Thermometer stands out as a remarkable instrument designed for precision temperature measurements. It combines the accuracy of complex and expensive bridges with innovative features that simplify the measurement process, making it an excellent value for both primary and secondary laboratories. Capable of calibrating SPRTs, PRTs, and thermistors, the 1954A offers exceptional measurement accuracy, especially in resistance ratio measurements (Rx/Rs), with an accuracy as good as 0.2 ppm for typical thermometry ratios and 0.06 ppm for ratios near unity.

The Fluke 1954A Super-Thermometer internal reference resistors are enclosed in a temperature-controlled oven, ensuring stability and minimizing errors due to changing ambient conditions. Moreover, its low measurement noise, unprecedented measurement speed, and the patent-pending "Ratio Self-Calibration" feature empower metrologists to verify and maintain instrument performance easily. With user-friendly calibration functions and the ability to calculate the effects of self-heating, the 1954A Super-Thermometer is a versatile and powerful tool for precision temperature measurements.

 

Specifications for the  FLUKE  1594A Calibration Super-Thermometer Include:

Input Resistance Range 0 to 500 kΩ
Display Resolution 0.1 to 0.000001
Sample Periods (seconds) 1,2,5, and 10
Ratio Range 0 to 10

 