Fluke

Fluke 1630

Ground Resistance Meter
Misuratore di corrente di dispersione a terra (Earth Ground Clamp) Tipo di misurazione
0,001 A – 30 A Gamma di misura della corrente di dispersione
1 mA Risoluzione
±2% + 3 cifre Precisione
50 Hz / 60 Hz Frequenza di misura
Richiedi scheda tecnica
Attributo Valore
Tipo di misurazione Misuratore di corrente di dispersione a terra (Earth Ground Clamp)
Gamma di misura della corrente di dispersione 0,001 A – 30 A
Risoluzione 1 mA
Precisione ±2% + 3 cifre
Frequenza di misura 50 Hz / 60 Hz
Apertura della pinza 53 mm
Display Display LCD retroilluminato
Alimentazione 4 batterie AA (1,5 V)
Grado di protezione IP40
Categoria di sicurezza CAT IV 300 V / CAT III 600 V
Modulo di calibrazione Fluke 1630

Modulo di riparazione Fluke 1630
Maximum file size: 40MB

No Related Posts

Ulteriori informazioni
Model1630

 Fluke 1630 Ground Resistance Meter

 

The  Fluke 1630 Ground Resistance Meter is  a  compact, rugged clamp meter that enables non-intrusive leakage cur measurement for earth ground loop testing.  The clamp-on ground testing technique provided by the Fluke 1630 simplifies ground loop testing and enables non-intrusive leakage cur measurement without breaking the circuit. Its compact and rugged design makes the  Fluke 1630 Ground Resistance Meter easy to use in small places and harsh environments. Handy features like €œdisplay hold " and continuity testing with an audible alarm, ensures additional convenience.  

Fluke 1630 Ground Resistance Meter  uses the stakeless testing method, which eliminates the need to disconnect parallel ground rods and find suitable locations for placing auxiliary ground stakes. This saves time and enables users such as industrial and utility electricians, and field service electricians and contractors, to perform earth ground loop tests in locations where it is not possible to use other techniques, such as inside buildings or on power pylons.  Fluke 1630 Ground Resistance Meter provides a large jaw opening of 35 mm (1.38 in) for tests on ground conductors and/or equipotential bus bars.  Automatically records and stores measured values with time saving memory function.

 

Specifications for the  Fluke 1630 Ground Resistance Meter Include:

Storage temp. range -20u00b0C to 60u00b0C (-4u00b0F to 140u00b0F)
Reference temp. range 23u00b0C u00b15u00b0C (73u00b0F u00b19u00b0F)
Storage humidity < 75% Rh
Operating humidity < 85% Rh

 