Fluke

Fluke 5790B

AC Measurement Standard
700 mV – 1000 V Gamma di misura della tensione AC
±2 ppm (riferimento a 1 kHz) Incertezza di misura (tensione AC)
10 Hz – 1 MHz Gamma di frequenza
1 MΩ in parallelo con 25 pF Impedenza di ingresso
Fino a 7 cifre Risoluzione di misura
Richiedi scheda tecnica
Attributo Valore
Gamma di misura della tensione AC 700 mV – 1000 V
Incertezza di misura (tensione AC) ±2 ppm (riferimento a 1 kHz)
Gamma di frequenza 10 Hz – 1 MHz
Impedenza di ingresso 1 MΩ in parallelo con 25 pF
Risoluzione di misura Fino a 7 cifre
Interfacce di comunicazione IEEE-488 (GPIB), RS-232
Temperatura operativa 18 °C – 28 °C
Alimentazione 100 V / 120 V / 220 V / 240 V AC, 50/60 Hz
Conformità e certificazioni ISO 17511, tracciabilità NIST
Dimensioni (L x A x P) 425 mm x 133 mm x 497 mm
Fluke 5790B Options:
  • 5790B - 03 - AC Measurement Standard + 30 MHz Wideband Option
  • 5790B - 05 - AC Measurement Standard + 50 MHz Wideband Option
  • 5790B - AF - AC Measurement Standard + 50 MHz Wideband Option Calibrated with WB cable
Modulo di calibrazione Fluke 5790B

Modulo di riparazione Fluke 5790B
Maximum file size: 40MB

No Related Posts

Ulteriori informazioni
Model5790B

FLUKE 5790B AC Measurement Standard  

 

The Fluke 5790B AC Measurement Standard is a versatile and highly accurate tool designed for demanding calibration applications. It offers the precision of a thermal transfer standard combined with the user-friendliness of a digital multimeter. With an absolute AC voltage measurement uncertainty as low as   ± 24 ppm, it meets the stringent AC voltage, AC current, and wideband verification requirements of various calibrators, amplifiers, and transfer standards.

The Fluke 5790B covers an extensive alternating voltage range from 600 µV to 1000 V and a frequency range from 10 Hz to 1 MHz. It can make direct absolute or relative cur measurements with Fluke A40B Cur Shunts, eliminating the need for manual calculations. The device boasts a user-friendly interface, expanded capabilities, and improved specifications, making it a trusted choice for calibration laboratories. Its solid-state thermal RMS sensor and hermetically sealed thin-film resistor networks ensure accuracy and reliability. The Fluke 5790B offers various input options, supports automated measurements, and interfaces with PCs for integration into automated systems, making it a versatile and dependable instrument for precision measurements.

 

Specifications for the  FLUKE  5790B AC Measurement Standard Include:

AC Voltage Range 600   µV to 1000 V
Frequency Range 10 Hz to 1 MHz
AC Voltage Measurement Uncertainty ± 24 ppm
   

 

Clicky Copyright © 2013-present Magento, Inc. All rights reserved.