Fluke

Fluke 709H

Precision Current Loop Calibrator with HART
0 mA - 24 mA Intervallo di uscita corrente
0,001 mA Risoluzione uscita corrente
±0,015% del valore impostato ±2 µA Precisione uscita corrente
Fino a 10.000 psi (690 bar) Intervallo di misura della pressione
±0,025% del fondo scala Precisione di misura della pressione
Richiedi scheda tecnica
Attributo Valore
Intervallo di uscita corrente 0 mA - 24 mA
Risoluzione uscita corrente 0,001 mA
Precisione uscita corrente ±0,015% del valore impostato ±2 µA
Intervallo di misura della pressione Fino a 10.000 psi (690 bar)
Precisione di misura della pressione ±0,025% del fondo scala
Display Display grafico retroilluminato ad alta risoluzione
Alimentazione 6 batterie AA o alimentatore esterno
Comunicazione Interfaccia USB per connessione PC
Certificazione ATEX/IECEx per uso in aree pericolose (Zone 0, 1, 2)
Temperatura operativa -10 °C a +50 °C
Fluke 709H Options:
  • 709H - 709H/TRACK - Optional software/cable for uploading HART device configuration files; outputs data in .csv or .txt format
Modulo di calibrazione Fluke 709H

Modulo di riparazione Fluke 709H
Maximum file size: 40MB

No Related Posts

Ulteriori informazioni
Model709H

Fluke 709H  Precision Cur Loop Calibrator with HART

 

The  Fluke 709H Precision Cur Loop Calibrator with HART is designed to save time and produce high-quality results. These calibrators are built around a user friendly interface with a quick-set rotary encoder knob. This tool reduces the time it takes to measure, or source, cur and power up a loop. The protective holster easily fits into a technician's hand and the large backlit display is easy to read, even in dark, cramped worked areas.  Fluke 709H features data lg which offers selectable capture with recording intervals of 1 to 60 seconds and a logging capacity of 9800 records or 99 individual sessions.

Fluke 709H Precision Cur Loop Calibrator with HART  includes HART communication and supports a select set of the HART universal and common practice commands.  The 709H adds HART communications and supports a select set of the HART universal and common practice commands. This makes the 709H unique as both an affordable, compact loop calibrator and powerful HART communication troubleshooting tool. In the communicator mode the user will be able to read basic device information, perform diagnostic tests, and trim the mA output on most HART enabled transmitters. In the past, this could only be done with a dedicated communicator, a high-end multifunction calibrator, or a laptop computer with HART modem. Fluke 709H will allow virtually any technician to service and support HART devices.

 

Specifications for the  Fluke 709H Precision Cur Loop Calibrator with HART Include:

Ranges mA (0 to 24mA) and Volts (0 to 30VDC)
Resolution 1 µA on mA ranges and 1 mV on voltage range
Accuracy 0.01% +/- 2 counts, all ranges (@23 ° +/- 5 °C)
Stability 20 ppm of F.S. / °C from -10 to 18 °C and 28 to 55 °C

 