Fluke 729

| Attributo | Valore |
|---|---|
| Intervallo di pressione | 0 - 300 psi (0 - 2068 kPa) |
| Accuratezza | ±0,05% del fondo scala |
| Alimentazione | Batterie AA (4x) o adattatore CA |
| Display | Display grafico retroilluminato |
| Pompa interna | Pompa pneumatica integrata con valvola di sfiato fine |
| Unità di misura | psi, kPa, bar, mbar, inH₂O, cmH₂O, mmHg, inHg, kg/cm² |
| Connessione al processo | Attacco da 1/4" NPT maschio |
| Memoria | Fino a 20 set di dati memorizzabili |
| Temperatura di esercizio | -10°C a +50°C |
| Certificazioni | CE, conforme alle normative di sicurezza IEC 61010-1 |
Fluke 729 Options:
- 729 - 30G - 30 psi, 2 Bar Automatic Pressure Calibrator, no wireless communication
- 729 - 150G - 150 psi, 10 Bar Automatic Pressure Calibrator, no wireless communication
- 729 - 300G - 300 psi, 20 Bar Automatic Pressure Calibrator, no wireless communication
- 729 - 30G FC - 30 psi, 2 Bar Automatic Pressure Calibrator, with Fluke Connect wireless communication
- 729 - 150G FC - 150 psi, 10 Bar Automatic Pressure Calibrator, with Fluke Connect wireless communication
- 729 - 300G FC - 300 psi, 20 Bar Automatic Pressure Calibrator, with Fluke Connect wireless communication
- 729CN - 200K - 200 kPa Automatic Pressure Calibrator, China, no wireless communication
- 729CN - 1M - 1 MPa Automatic Pressure Calibrator, China, no wireless communication
- 729CN - 2M - 2 MPa Automatic Pressure Calibrator, China, no wireless communication
- 729CN - 200K FC - 200 kPa Automatic Pressure Calibrator, China, with Fluke Connect wireless communication
- 729CN - 1M FC - 1 MPa Automatic Pressure Calibrator, China, with Fluke Connect wireless communication
- 729CN - 2M FC - 2 MPa Automatic Pressure Calibrator, China, with Fluke Connect wireless communication
- 729JP - 200K - 200 kPa Automatic Pressure Calibrator, Japan, no wireless communication
- 729JP - 1M - 1 MPa Automatic Pressure Calibrator, Japan, no wireless communication
- 729JP - 2M - 2 MPa Automatic Pressure Calibrator, Japan, no wireless communication
- 729JP - 200K FC - 200 kPa Automatic Pressure Calibrator, Japan, with Fluke Connect wireless communication
- 729JP - 1M FC - 1 MPa Automatic Pressure Calibrator, Japan, with Fluke Connect wireless communication
- 729JP - 2M FC - 2 MPa Automatic Pressure Calibrator, Japan, with Fluke Connect wireless communication
| Model | 729 |
|---|
FLUKE 729 Auto. Pressure Calibrator
The Fluke 729 Auto. Pressure Calibrator is designed to simplify the pressure calibration process and provide faster and more accurate test results. The 729 makes pressure calibration easier than ever with an internal electric pump that provides automatic pressure generation and regulation in an easy-to-use, rugged, portable package. Fluke 729 allows you to simply type in a target pressure, and the calibrator will automatically pump to the desired set-point. Then, internal fine adjustment control automatically stabilizes the pressure at the requested value.
The Fluke 729 Auto. Pressure Calibrator can automatically test multiple pressure test points and automatically document the results. Calibration is as easy as typing in the starting and ending pressure and the number of test points and tolerance level. Built-in HART communication capabilities enable HART transmitter mA adjustments, light HART configuration and the ability to adjust to applied 0 % and 100 % values. With three ranges to choose from, 30 psi (2 bar, 200 kPa), 150 psi (10 bar, 1 MPa) and 300 psi (20 bar, 2 MPa), Fluke 729 Automatic Pressure Calibrator is designed to perform when and where you need them. Technicians can upload and manage documented calibration results with DPCTrack2 calibration management software, making it easy to manage instrumentation, create scheduled tests and reports, and manage calibration data.
Specifications for the FLUKE 729 Auto. Pressure Calibrator Include:
| Psi Range, Resolution | -12.000 to 300.000 psi |
| Voltage measurement range | 0 V dc to 30 V dc |
| Cur measurement range | 0 mA to 24 mA |
| Accuracy | 0.01 % ± 2 LSD all ranges (at 23 °C ± 5 °C) |