Hipotronics

Hipotronics 880PL-DC

DC Hipot, 80 kV, 10 mA, Touchscreen LCD
Test di alta tensione in corrente continua (DC) Tipo di Test
80 kV DC Tensione di Uscita Massima
5 mA Corrente di Uscita Massima
400 W Potenza Nominale
Controllo continuo da 0 a tensione massima Regolazione della Tensione
Richiedi scheda tecnica
Attributo Valore
Tipo di Test Test di alta tensione in corrente continua (DC)
Tensione di Uscita Massima 80 kV DC
Corrente di Uscita Massima 5 mA
Potenza Nominale 400 W
Regolazione della Tensione Controllo continuo da 0 a tensione massima
Misurazione della Corrente Microamperometro digitale integrato
Protezione Interruzione automatica in caso di scarica o sovracorrente
Alimentazione Richiesta 115/230 V CA, 50/60 Hz
Conformità Normativa IEEE, ASTM, IEC standard per test dielettrici
Applicazioni Tipiche Test su cavi, trasformatori, condensatori e apparecchiature elettriche ad alta tensione
Hipotronics 880PL-DC Options:
  • 880PL-DC - HHDA13-280 - 120kV rated grounding stick
  • 880PL-DC - HH-SAFE - Safety strobe light with magnetic base
  • 880PL-DC - HH-FS - Foot operated interlock switch
  • 880PL-DC - EXT-WARN - Warranty Extensions to 2 or 3 years
Modulo di calibrazione Hipotronics 880PL-DC

Modulo di riparazione Hipotronics 880PL-DC
Maximum file size: 40MB

No Related Posts

Ulteriori informazioni
Model880PL-DC

HAEFELY / HIPOTRONICS 880PL-DC HIPOT TESTER

 

    The Haefely/Hipotronics 880PL-DC DC Hipot is a modern solution for testing the insulation strength of electrical apparatus. Outfitted with a state-of-the-art digital interface and extensive safety features, the 880PL-DC ensures simplistic operation, accurate results, and operator safety under all circumstances. It measures output voltage, leakage current, insulation resistance (IR), and polarization index (PI).    Test parameters such as target voltage, maximum leakage, ramp rate, and dwell time are all easily adjustable with the 880PL-DC hipot tester.  

The 880PL-DC Hipot features the most accurate kilovoltmeter readings regardless of load current. Voltage measurements are taken directly at the output of the high voltage transformer, while cur is measured at the return leg to ensure the highest accuracy. Output power is created through a full-wave, voltage multiplier.  Safe operation is built in, with interlock, emergency stop, and battery backup for display meters if input power is lost.  All models of the Haefely/Hipotronics 880PL-DC hipot testers are self-contained in a rugged and durable enclosure.

 

Features of the  Haefely / Hipotronics 880PL-DC Hipot Tester  include:

  • DC hipot test up to 40kV or 80kV, 10mA
  • Full-wave voltage doubling rectifier
  • Recorded test results and data transfer via USB 2.0
  • Adjustable test parameters such as target voltage, maximum leakage, ramp rate, and dwell time
  • Automatic grounding of power supply and test object when high voltage is turned OFF
  • Accurate cur measurement and guard circuit designed to eliminate stray leakage currents

 

 

 

Click Here To See Other  