Manufacturer Logo
Keysight (Agilent)

Keysight (Agilent) J7211A

Attenuation Control Unit, 6 GHz, 0 to 121 dB, 1 dB Steps
0 dB - 101 dB Gamma di attenuazione
1 dB Passo di attenuazione
DC - 4 GHz Gamma di frequenza
50 Ohm Impedenza
1 W (30 dBm) Potenza massima in ingresso
Richiedi scheda tecnica
Attributo Valore
Gamma di attenuazione 0 dB - 101 dB
Passo di attenuazione 1 dB
Gamma di frequenza DC - 4 GHz
Impedenza 50 Ohm
Potenza massima in ingresso 1 W (30 dBm)
Connettori SMA (femmina)
Tensione di alimentazione +15 V DC
Interfaccia di controllo Bus a controllo parallelo TTL
Temperatura operativa 0°C - 55°C
Dimensioni (L x A x P) 212 mm x 88 mm x 318 mm
Keysight (Agilent) J7211A Options:
  • J7211A - 001 - Type-N (f) connector
  • J7211A - 002 - SMA (f) connector
  • J7211A - UK6 - Commercial calibration certificate with test data
  • J7211A - 908 - Rackmount Kit, 1 instrument
  • J7211A - 909 - Rackmount Kit, 2 instruments
Modulo di calibrazione Keysight (Agilent) J7211A

Modulo di riparazione Keysight (Agilent) J7211A
Maximum file size: 40MB

No Related Posts

Ulteriori informazioni
ModelJ7211A

KEYSIGHT J7211A

The Keysight  J7211A attenuation control unit provides an integrated solution for R&D and manufacturing engineers in wireless communication, aerospace and defense and electronic component industries. Operating from DC to 6 GHz, the J7211A provides attenuation up to 121 dB with a 1 dB step size. A unique attenuation sweep function lets users  select the start / stop attenuation, step size, dwell time and number of cycles for your application. The Keysight J7211A offers exceptional < 0.03 dB insertion loss repeatability per section for the entire 5 million cycles which reduces your cost of ownership.

Designed in a compact half-rack, 2 unit high-form factor, the Keysight J7211A ensures ease-of-use in benchtop applications and greater efficiency and throughput in ATE testing. GPIB, USB and LAN connectivity (LXI Class C Compliant) allow easy remote control and triggering.

Features and specifications of the Keysight J7211A Attenuation Control Unit include:

Attenuator Control Capability

  • Attenuation sweep function €“ define the sweep time, number of cycles and step size for your application
  • Relative attenuation step function - set attenuation relative to any value
  • Attenuation steps - 0 dB to 121 dB, 121 dB to 0 dB, or back and forth for the preset number of cycles (1 to 1000)
  • User selectable sweep time - 50 ms to 10 s; 50 ms incremental

Specifications

  • 0.03 dB insertion loss repeatability per section for the entire 5 million cycles
  • Excellent attenuation accuracy and flatness

Remote Control and Programming

  • LXI Class C compliant for easy remote integration