Manufacturer Logo
Keysight (Agilent)

Keysight (Agilent) N432A

Thermistor Power Meter
100 kHz - 18 GHz Intervallo di frequenza
-70 dBm a +44 dBm Intervallo di potenza misurata
Sensore di potenza termica N8480 Series Tipo di sensore compatibile
±0,02 dB (tipico) Incertezza di misurazione
Display grafico LCD retroilluminato Display
Richiedi scheda tecnica
Attributo Valore
Intervallo di frequenza 100 kHz - 18 GHz
Intervallo di potenza misurata -70 dBm a +44 dBm
Tipo di sensore compatibile Sensore di potenza termica N8480 Series
Incertezza di misurazione ±0,02 dB (tipico)
Display Display grafico LCD retroilluminato
Numero di canali 1 canale
Interfacce di comunicazione GPIB, USB, LAN (LXI Core 2011)
Tensione di alimentazione 100 - 240 V CA, 50/60 Hz
Temperatura operativa 0 °C a +55 °C
Dimensioni (L x A x P) 212 mm x 88 mm x 272 mm
Keysight (Agilent) N432A Options:
  • N432A - 478A-H63 - Frequency range 100 kHz to 1 GHz, max SWR 1.8 to 300 kHz, 1.3 to 1 GHz
  • N432A - 478A-H75 - Frequency range 1 MHz to 1 GHz, max SWR 1.3 except 1.05 at 50 MHz
  • N432A - 478A-H76 - Frequency range 1 MHz to 1 GHz, max SWR 1.3 except 1.05 at 50 MHz. Standard lab calibration at 50 MHz
  • N432A - N4998A - Thermistor sensor adaptor cable 1.5 m (5 ft)
  • N432A - N4998B - Thermistor sensor adaptor cable 3 m (10 ft)
  • N432A - N4998C - Thermistor sensor adaptor cable 6.1 m (20 ft)
  • N432A - 908 - Rackmount kit with 1 unit with blank filler included
  • N432A - 909 - Rackmount kit with 2 units side-by-side
  • N432A - 0BK - English language user guide and English programming guide
  • N432A - ABJ - Japanese user guide and English programming guide
  • N432A - 0BF - English language programming guide
  • N432A - A6J - Certificate of compliance calibration - ANSI/NCSL Z540
  • N432A - 1A7 - Compliant calibration test data - ISO17025
Modulo di calibrazione Keysight (Agilent) N432A

Modulo di riparazione Keysight (Agilent) N432A
Maximum file size: 40MB

No Related Posts

Ulteriori informazioni
ModelN432A

AGILENT N432A

The Agilent N432A Power Meteris the replacement for Agilent's legacy 432A analog thermistor power meter. The single channel, average RF power meter operates with the Agilent 8478B and 478A thermistor mounts. The N432A and thermistor mount pair is perfect for applications that require high measurement accuracy, particularly in metrology and calibration lab environments. The enhanced thermistor power meter comes with a digital color LCD display, and user-friendly front panel interface. Its built-in calibration factor table provides a more convenient and accurate method of storing calibration factors as compared to the old knob-turning approach of the 432A. The Agilent N432A is LXI-C compliant, and programmable via GPIB, USB and LAN.

Features and specifications of the Agilent N432A Power Meter include:

  • Frequency range: 100 kHz to 18 GHz (sensor dependent)
  • Dynamic range: -30 dBm to +10 dBm
  • High Accuracy ( ‰¤ 0.1% ± 0.5 uW), excellent for 1 mW transfer calibration (with 478A-H75/H76)
  • Built-in 6.5 digits ADC eliminates the need of external DMM.
  • Selectable bridge resistance (100/200/300/400 Ω)
  • Remote interface flexibility (GPIB, USB, LXI-C)
  • Digital color LCD display
Clicky Copyright © 2013-present Magento, Inc. All rights reserved.