Manufacturer Logo
Keysight (Agilent)

Keysight (Agilent) PV8922A

Photovoltaic Array Simulator, 2000V, 30A, 20kW
400 MHz – 2,7 GHz Gamma di frequenza
GSM, GPRS, EDGE, WCDMA, HSPA, LTE Tecnologia supportata
Da -120 dBm a +10 dBm Potenza di uscita RF
50 Ohm Impedenza
GPIB, USB, LAN (LXI) Interfaccia di comunicazione
Richiedi scheda tecnica
Attributo Valore
Gamma di frequenza 400 MHz – 2,7 GHz
Tecnologia supportata GSM, GPRS, EDGE, WCDMA, HSPA, LTE
Potenza di uscita RF Da -120 dBm a +10 dBm
Impedenza 50 Ohm
Interfaccia di comunicazione GPIB, USB, LAN (LXI)
Alimentazione 100 – 240 V CA, 50/60 Hz
Consumo energetico Massimo 350 W
Temperatura operativa 0 °C – 55 °C
Dimensioni (L x A x P) 425 mm x 222 mm x 500 mm
Peso Circa 18 kg
Keysight (Agilent) PV8922A Options:
  • DG9000A - DG9104A - License to control up to 4 PV simulators in DG9000A software
  • DG9000A - DG9108A - License to control up to 8 PV simulators in DG9000A software
  • DG9000A - DG9112A - License to control up to 12 PV simulators in DG9000A software
Modulo di calibrazione Keysight (Agilent) PV8922A

Modulo di riparazione Keysight (Agilent) PV8922A
Maximum file size: 40MB

No Related Posts

Ulteriori informazioni
ModelPV8922A

 Keysight (Agilent) PV8922A Photovoltaic Array Simulator  

 

Whether your inverter has one or twelve inputs / MPPTs, Keysight's PV8922A Photovoltaic/Solar Inverter Test Solution can help you go beyond the test standards to maximize performance and bankability.  With the PV8922A and DG9000A software you can simultaneously control and test from one to twelve PV inverter inputs / MPPTS, enabling you to go beyond the test standards, optimizing your inverters to beat the competition.  The PV8922A PV array simulators' autoranging output characteristic makes it much more flexible than rectangular, or traditional, output characteristic power supplies because they expand the power curve, giving you more voltage and cur combinations in one power supply.

The Keysight PV8922A PV simulators are autoranging, programmable DC power sources that simulate the output characteristics of a photovoltaic array under diffe environmental conditions (temperature, irradiance, age, cell technology, etc.) enabling you to quickly and comprehensively test inverter MPPT algorithms and inverter efficiency.  The PV8922A has two solar array simulation (SAS) operating modes: curve mode where the PV array simulator quickly creates the curve mathematically and table mode where you can enter the precise I-V curve with up to 1024 points and  table mode, the SAS characteristic curve is created from up to 1024 user-specified voltage/cur points to match specific I-V curves.

 

Specifications for the  Keysight (Agilent) PV8922A Photovoltaic Array Simulator Include:

Voltage 2000V
Current 30A
Total Power 20kW
AC Input 3 phase; 380 €“ 480 VAC

 

 