Manufacturer Logo
Keysight (Agilent)

Keysight (Agilent) PV8931A

Photovoltaic Array Simulator, 1500V, 60A, 30kW
Modulo di alimentazione PXI Tipo di modulo
Fino a 60 V Tensione di uscita
Fino a 2 A Corrente di uscita massima
2 canali indipendenti Numero di canali
PXI/PXIe Interfaccia di comunicazione
Richiedi scheda tecnica
Attributo Valore
Tipo di modulo Modulo di alimentazione PXI
Tensione di uscita Fino a 60 V
Corrente di uscita massima Fino a 2 A
Numero di canali 2 canali indipendenti
Interfaccia di comunicazione PXI/PXIe
Risoluzione della tensione 1 mV
Risoluzione della corrente 100 µA
Compatibilità software Compatibile con Keysight Command Expert e IVI Driver
Temperatura di esercizio 0 °C – 55 °C
Dimensioni del modulo Formato 3U PXI, 1 slot
Keysight (Agilent) PV8931A Options:
  • DG8901A - DG8901A - License for SAS Control Pro, enables automated static and dynamic EN50530 test
  • DG9000A - DG9104A - License to control up to 4 PV simulators in DG9000A software
  • DG9000A - DG9108A - License to control up to 8 PV simulators in DG9000A software
  • DG9000A - DG9112A - License to control up to 12 PV simulators in DG9000A software
Modulo di calibrazione Keysight (Agilent) PV8931A

Modulo di riparazione Keysight (Agilent) PV8931A
Maximum file size: 40MB

No Related Posts

Ulteriori informazioni
ModelPV8931A

 KEYSIGHT PV8931A Photovoltaic Array Simulator  

 

The Keysight PV8931A Photovoltaic Array Simulator enables you to develop, verify and optimize the performance of your inverter maximum power point tracking algorithms. Developing and verifying the performance of inverter maximum power point tracking (MPPT) algorithms is challenging. MPPT algorithms are complex, and under-the-sun testing with a comprehensive set of temperature and irradiance conditions is difficult, expensive and time consuming.  As inverters increase in power, the size of the test array would become unmanageable. As they increase in number of inputs on a single inverter, the complexity of test changes exponentially. The only practical test method is to use a laboratory test solution that can simulate from one to many real-world solar array strings.

The Keysight PV8931A Photovoltaic Array Simulators can simulate the output characteristics of a real-world photovoltaic array. The PV8931A PV array simulator is an autoranging, programmable DC power source that can quickly simulate I-V curve characteristics under diffe environmental conditions (temperature, irradiance, age, cell technology and more), enabling you to quickly and comprehensively test your solar inverters.  The Keysight Technologies PV8900 Series PV array simulator provides up to 30 kW autoranging, single-output programmable DC power. The autoranging output characteristic enable a wide range of voltage and cur combinations at full power.

 

Specifications for the  KEYSIGHT PV8931A Photovoltaic Array Simulator Include:

Max Voltage 1500 V
Max  Current 60 A
Total Power 30 kW

Transient response

300 µs

 

Clicky Copyright © 2013-present Magento, Inc. All rights reserved.