Keysight (Agilent) N9030B-508

| Attributo | Valore |
|---|---|
| Gamma di Frequenza | 3 Hz - 8,4 GHz |
| Larghezza di Banda di Analisi | fino a 255 MHz |
| Livello di Rumore Visualizzato (DANL) | -171 dBm/Hz (tipico) |
| Gamma Dinamica | 78 dB |
| Fase di Rumore | -108 dBc/Hz a 10 kHz di offset (tipico) |
| Livello Massimo di Ingresso | +30 dBm |
| Impedenza di Ingresso | 50 Ohm |
| Gamma di Attenuazione | 0 - 70 dB |
| Precisione dell'Ampiezza | ±0,19 dB (tipico) |
| Interfacce di Connettività | USB, LAN (LXI), GPIB |
Keysight Technologies N9030B-508 Options:
- N9030B-508 - P03 - Preamplifier, 100 kHz to 3.6 GHz
- N9030B-508 - P08 - Preamplifier, 100 kHz to 8.4 GHz
- N9030B-508 - P13 - Preamplifier, 100 kHz to 13.6 GHz
- N9030B-508 - P26 - Preamplifier, 100 kHz to 26.5 GHz
- N9030B-508 - EA3 - Electronic attenuator up to 3.6 GHz; 1 dB steps, 0 to 24 dB
- N9030B-508 - B40 - 40 MHz analysis bandwidth
- N9030B-508 - B85 - 85 MHz analysis bandwidth
- N9030B-508 - B1X - 160 MHz analysis bandwidth
- N9030B-508 - B2X - 255 MHz analysis bandwidth (Requires Options EP0 and MPB)
- N9030B-508 - B5X - 510 MHz analysis bandwidth (Requires Options EP0 and MPB)
- N9030B-508 - MPB - Microwave preselector bypass
- N9030B-508 - EP0 - Enhanced phase noise, DDS LO
- N9030B-508 - LNP - Low noise path
- N9030B-508 - EXM - External mixing
- N9030B-508 - FP2 - Fast power (requires Option B40, B85, B1X, B2X, or B5X)
- N9030B-508 - BBA - I/Q baseband inputs, analog
- N9030B-508 - RT1 - Real-time analysis up to maximum available BW, basic detection
- N9030B-508 - RT2 - Real-time analysis up to maximum available BW, optimum detection
- N9030B-508 - RTR - Real-time spectrum recorder and analyzer application
- N9030B-508 - RTS - Real-time I/Q data streaming
- N9030B-508 - FT1 - Frequency mask trigger, basic detection
- N9030B-508 - FT2 - Frequency mask trigger, optimum detection
- N9030B-508 - EMC - Basic EMI precompliance
- N9030B-508 - EDP - Enhanced display package (spectrogram, trace zoom, and zone span)
- N9030B-508 - ESC - External source control for Keysight EXG, MXG, and PSG signal generators
- N9030B-508 - SSD - Additional removable solid-state drive
- N9030B-508 - SF1 - Exclude launch program (security feature)
- N9030B-508 - SF2 - Prohibit saving results (security feature)
- N9030B-508 - CR3 - Second IF output
- N9030B-508 - CRP - Arbitrary IF out (10 to 75 MHz in 500 kHz steps)
- N9030B-508 - YAV - Y-axis video out
- N9030B-508 - ALV - Aux log video out
- N9030B-508 - UK6 - Commercial calibration certificate with test data
- N9030B-508 - AMG - Keysight Calibration + Uncertainties + Guardbanding (accredited cal)
- N9030B-508 - A6J - ANSI Z540-1-1994 Calibration
| Model | N9030B-508 |
|---|
Il Keysight (Aglient) N9030B‑508 offre un’analisi spettrale RF precisa fino a 8,4 GHz con banda in tempo reale opzionale di 1 GHz, garantendo un eccellente DANL per la rilevazione di segnali a basso livello in applicazioni complesse 5G NR, radar e militari.
Questo analizzatore avanzato supporta misurazioni chiave come EVM, ACLR, ACP e altro, con integrazione fluida agli strumenti Keysight PathWave e interfacce USB, LAN e GPIB sul pannello frontale.
Testwall può fornire l’usato Keysight (Aglient) N9030B‑508, completamente testato. Con supporto esperto e consegna globale, Testwall garantisce strumenti ad alte prestazioni con affidabilità e qualità di servizio senza pari. Per favore contattateci direttamente se avete bisogno di calibrazione o riparazione del Keysight (Aglient) N9030B‑508.