Keysight (Agilent)
Keysight (Agilent) N9030B-544
44 GHz PXA Signal Analyzer, 2.4 mm (m)
44 GHz Frequenza Massima
2 Hz Frequenza Minima
510 MHz Larghezza di Banda di Analisi
78 dB Gamma Dinamica
-171 dBm/Hz (tipico) Livello di Rumore Medio Visualizzato (DANL)

| Attributo | Valore |
|---|---|
| Frequenza Massima | 44 GHz |
| Frequenza Minima | 2 Hz |
| Larghezza di Banda di Analisi | 510 MHz |
| Gamma Dinamica | 78 dB |
| Livello di Rumore Medio Visualizzato (DANL) | -171 dBm/Hz (tipico) |
| Fase di Rumore | -130 dBc/Hz a 10 kHz di offset (tipico) |
| Gamma di Misura dell'Ampiezza | +30 dBm (ingresso massimo) |
| Interfacce di Connettività | LAN, USB, GPIB |
| Display | Schermo touchscreen LCD a colori da 12,1 pollici |
| Alimentazione | 100-240 V CA, 50/60 Hz |
Keysight Technologies N9030B-544 Options:
- N9030B-544 - P03 - Preamplifier, 100 kHz to 3.6 GHz
- N9030B-544 - P08 - Preamplifier, 100 kHz to 8.4 GHz
- N9030B-544 - P13 - Preamplifier, 100 kHz to 13.6 GHz
- N9030B-544 - P26 - Preamplifier, 100 kHz to 26.5 GHz
- N9030B-544 - P44 - Preamplifier, 100 kHz to 44 GHz
- N9030B-544 - EA3 - Electronic attenuator up to 3.6 GHz; 1 dB steps, 0 to 24 dB
- N9030B-544 - B40 - 40 MHz analysis bandwidth
- N9030B-544 - B85 - 85 MHz analysis bandwidth
- N9030B-544 - B1X - 160 MHz analysis bandwidth
- N9030B-544 - MPB - Microwave preselector bypass
- N9030B-544 - EP0 - Enhanced phase noise, DDS LO
- N9030B-544 - LNP - Low noise path
- N9030B-544 - EXM - External mixing
- N9030B-544 - FP2 - Fast power; accelerates power measurements such as ACPR
- N9030B-544 - BBA - I/Q baseband inputs, analog; single-ended/differential, 50 Ω/1 MΩ impedance
- N9030B-544 - RT1 - Real-time analysis up to maximum available BW, basic detection
- N9030B-544 - RT2 - Real-time analysis up to maximum available BW, optimum detection
- N9030B-544 - RTR - Real-time spectrum recorder and analyzer application
- N9030B-544 - RTS - Real-time I/Q data streaming
- N9030B-544 - FT1 - Frequency mask trigger, basic detection
- N9030B-544 - FT2 - Frequency mask trigger, optimum detection
- N9030B-544 - EMC - Basic EMI precompliance
- N9030B-544 - EDP - Enhanced display package; includes spectrogram, trace zoom, and zone span
- N9030B-544 - ESC - External source control for Keysight EXG, MXG, and PSG signal generators
- N9030B-544 - SSD - Additional removable solid-state drive
- N9030B-544 - SF1 - Exclude launch program; prevents launching of Windows programs from instrument application
- N9030B-544 - SF2 - Prohibit saving results; prevents saving/recall of measurement results or user configurations
- N9030B-544 - CR3 - Second IF output; wideband IF out
- N9030B-544 - CRP - Arbitrary IF out, 10 to 75 MHz (in 500 kHz steps)
- N9030B-544 - YAV - Y-axis video out; screen video (0-1 volt open circuit)
- N9030B-544 - ALV - Aux log video out; fast rise time video out
- N9030B-544 - UK6 - Commercial calibration certificate with test data
- N9030B-544 - AMG - Keysight Calibration + Uncertainties + Guardbanding (accredited cal)
- N9030B-544 - A6J - ANSI Z540-1-1994 Calibration
| Model | N9030B-544 |
|---|
Il Keysight (Agilent) N9030B-544 copre da 3 Hz a 44 GHz, con larghezza di banda in tempo reale fino a 1 GHz e supporto per il mixing esterno per test sub-THz. Offre eccellenti prestazioni in termini di rumore di fase e FM residuo.
Compatibile con 5G, LTE, radar e satelliti, modulare e scalabile per proteggere l’investimento a lungo termine con analisi completa del segnale vettoriale.
Testwall può fornire il Keysight (Agilent) N9030B-544 usato, completamente testato. Con supporto esperto e consegna globale, Testwall garantisce strumenti ad alte prestazioni con affidabilità superiore. Contattaci per calibrazione o riparazione del Keysight (Agilent) N9030B-544.