Power Ten P63C-101000D Options:
- P63C-101000D - C - Input Line Voltage: 190-253 VAC, 47-63 Hz (Standard)
- P63C-101000D - D - Input Line Voltage: 360-440 VAC, 47-63 Hz (Option)
- P63C-101000D - E - Input Line Voltage: 432-528 VAC, 47-63 Hz (Option)
- P63C-101000D - AB - Isolated Analog Input
- P63C-101000D - R - IEEE-488.2 Interface and RS-232C Interface
- P63C-101000D - J - Shaft Locks
- P63C-101000D - 990-323-90 - L Brackets (2 Required, for all P Series)
- P63C-101000D - 105-300-26 - Rack Slide Kit (for all P Series)
| Model | P63C-101000D |
|---|
Power Ten supplies, including the Power Ten P63C-101000D (P63C series) are a strong choice for semiconductor burn-in systems worldwide and are providing solutions to high power DC voltage requirements in many other diverse applications. These include:
- Process Control
- Medical Systems
- Production Test
- Electromagnets
- ATE
- Battery Chargers
- Ion Implant
- Radar Systems
- High Power Lasers
- Research / Labs
- All power supply designs from Power Ten employ the most reliable, efficient and cost-effective switching technology €“ including pulse width modulation (PWM) and zero crossing topology to achieve both high efficiency and high-density packaging. Highlights include: 3-Phase Input Power, Low Peak-to-Peak Ripple & Noise, CE & TUV, Optional IEEE 488.2 and RS 232 Remote Programming with SCPI Protocol
Other features and specifications of the Power Ten P63C-101000D include:
- Output: 10V, 1000A, 50mV Ouput P-P Ripple
- Input Voltage: 190-253 VAC, 47-63 Hz
- Input Cur @ 208 VAC (Typical): At 10.0 kW Output: 41 A (Operates from Delta or Wye Source)
- Dimensions: 19 " (W) X 5.25 " (H) X 22 " (D)
- AC Input Interface: 3 wire + GND (#10-32 threaded studs) (208 VAC)
- DC Output Interface: Bus bars with 0.390 " interface holes for output =50 VDC.
- Control/Monitor Interface: DB 25-pin female connector
- Regulation (Line or Load) Voltage: 0.1% of maximum rated output
- Current: 0.5% of maximum rated output
- Transient Response
- A 30% cur step load will recover to within ±2% of set voltage within 10 msec.
- Stability
- ±0.05% of set point per 8 hours after 30 minutes warm-up at fi xed line, load and temperature.
- Temperature Coefficient
- 0.02%/ °C of rated output voltage
- 0.03%/ °C of rated output current
- Operating Temperature
- 0 to +50 ° C, No derating
- Storage Temperature
- -20 to +70 °C
- Cooling
- Internal fans
- Controls (Front Panel)
- On/Off switch, DC volts adjust, DC amps adjust, OVP preset adjust (limit set)
- Meters/Indicators
- LCD DC voltmeter, ammeter and OVP limit set. LED indicators for voltage mode, cur mode. OVP fault and fault
- Built-In Protection
- Over Voltage, Cur limit Fold back, Over Temperature, Brown Out, Turn On Surge Limit, Slow Start
- Remote Control/Monitor (Rear Panel)
- On/Off control via contact closure, 6-120 VDC, TTL or CMOS switch, output voltage and cur monitor, OVP limit set, summary fault status on P60 Series.
- Remote Programming (Voltage (0 to 100%) Cur (0 to 100%)):
- Resistive: 0-5K ohms 0-5K ohms
- Voltage: 0-5 VDC or 10 VDC 0-5 VDC or 10 VDC
- Optional IEEE 488.2 and RS 232 Programming with SCPI protocol
- Remote Sensing:
- Terminals provided to sense output voltage at load
- Operational Features:
- Master/Slave, Series, Parallel