Audio Analyzer, DC to 110 kHz
10 Hz – 22 kHz Gamma di frequenza
16 canali di ingresso analogici Numero di canali
24 bit Risoluzione ADC
Fino a 120 dB Dinamica
< -100 dB Distorsione armonica totale (THD+N)
Richiedi scheda tecnica
Attributo Valore
Gamma di frequenza 10 Hz – 22 kHz
Numero di canali 16 canali di ingresso analogici
Risoluzione ADC 24 bit
Dinamica Fino a 120 dB
Distorsione armonica totale (THD+N) < -100 dB
Impedenza di ingresso 200 kΩ (bilanciato)
Livello massimo di ingresso +24 dBu
Interfaccia di comunicazione IEEE 488 (GPIB) / USB / RS-232
Compatibilità software Compatibile con Rohde & Schwarz UPL tramite espansione opzionale
Alimentazione 100 – 240 V AC, 50/60 Hz
Rohde & Schwarz UPL16 Options:
  • UPL16 - UPL-B1 - Low Distortion Generator
  • UPL16 - UPL-B2 - Digital Audio I/O 48 kHz
  • UPL16 - UPL-B29 - Digital Audio I/O 96 kHz
  • UPL16 - UPL-B21 - Digital Audio Protocol
  • UPL16 - UPL-B22 - Jitter and Interface Test
  • UPL16 - UPL-B23 - Coded Audio Signal Generation
  • UPL16 - UPL-B4 - Remote Control
  • UPL16 - UPL-B5 - Audio Monitor
  • UPL16 - UPL-B6 - Extended Analysis Functions
  • UPL16 - UPL-B7 - Hearing Aids Test Accessories
  • UPL16 - UPL-B8 - Mobile Phone Test Set
  • UPL16 - UPL-B9 - 3G Mobile Phone Tests
  • UPL16 - UPL-B10 - Universal Sequence Controller
  • UPL16 - UPL-B11 - LAN Interface for R&S UPL06/66
  • UPL16 - UPL-B33 - Line Measurement to ITU-T O.33
  • UPL16 - UPL-Z1 - XLR/BNC Adapter Set
  • UPL16 - UPL-U3 - 150 Ω Modification
Modulo di calibrazione Rohde & Schwarz UPL16

Modulo di riparazione Rohde & Schwarz UPL16
Maximum file size: 40MB

No Related Posts

Ulteriori informazioni
ModelUPL16

Rohde & Schwarz UPL16 Audio Analyzer, DC to 110 kHz

The R&S UPL16 Audio Analyzer provides all the necessary audio signals and performs acoustical measurements GSM Mobile phone audio testing. The CMD80 or CMU200 Digital radio Communication Tester is used to establish the call. For some test cases the speech codec is also used.

The R&S UPL16  Audio Analyzer  has the same superior analysis concept as all members of the R&S UPL family. The instrument is able to handle both analog and digital processing. It carries out practically all types of measurement in the audio range from frequency response measurements to distortion measurements, FFT analysis, etc.

All the details about test functions and concept of operation can be found in the data sheet of the Audio Analyzer R&S UPL. The R&S UPL16 is especially designed for acoustical tests on GSM mobiles. It is equipped with the digital audio interface (DAI) as defined in GSM phase 2 recommendation 11.10, section 36.4. Thanks to this interface the R&S UPL16 can act as a system simulator or simulate a mobile.  

To drive an artificial head directly without additional amplifiers, the generator output of the R&S UPL16 is matched to the impedance of the artificial mouth by a built-in transformer on the rear panel of the R&S UPL16. GSM 11.10, section 30 defines 15 speech teleservices tests for GSM mobiles, generally referred to as acoustical test cases.  

 

Clicky Copyright © 2013-present Magento, Inc. All rights reserved.