Seitron S9000 Options:
- S9000 - O - O2 Sensor (0 .. 25.0% vol) - Included Standard
- S9000 - C - Standard CO Sensor w/ H2 Compensation (0-8000 ppm)
- S9000 - CL - LOW-Range CO Sensor (0-500 ppm)
- S9000 - CM - MID-Range CO Sensor (0-20,000 ppm)
- S9000 - CH - HIGH-Range CO Sensor (0-100,000 ppm)
- S9000 - N - Standard NO/NOx Sensor (0-5000 ppm)
- S9000 - NL - LOW NO/NOx Sensor (0-500 ppm)
- S9000 - D - Standard NO2 Sensor (0-1000 ppm)
- S9000 - DL - LOW NO2 Sensor (0-500 ppm)
- S9000 - S - Standard SO2 Sensor (0-5000 ppm)
- S9000 - SL - LOW SO2 Sensor (0-500 ppm)
- S9000 - H - Standard H2S Sensor (0-5000 ppm)
- S9000 - HL - LOW H2S Sensor (0-500 ppm)
- S9000 - G - H2 Sensor (0-2000 ppm)
- S9000 - C - Standard CxHy Sensor (0-5%)
- S9000 - A - Standard Ammonia (NH3) Sensor (0-500 ppm)
- S9000 - IR - NDIR Bench: CO2 NDIR Sensor (0-50%), CxHy NDIR Sensor (0-100,000 ppm), and High CO NDIR Sensor (0-50%) - counts as 3 gas sensors
- S9000 - O (Table B) - No IR Bench Included
- S9000 - 12 - 12" (300mm) Probe, 1112°F (600°C) max, with 10' (3m) Dual Hose - Included With Standard Kit
- S9000 - 30 - 30" (750mm) Probe, 1470°F (800°C) max, with 10' (3m) Dual Hose (AASF35)
- S9000 - 40 - 40" (1000mm) Probe, 1470°F (800°C) max, with 10' (3m) Dual Hose (AASF36)
- S9000 - 12H - 12" (300mm) Probe, 1112°F (600°C) max, with 10' (3m) HEATED Hose and HEATED Probe Head (AASR03)
- S9000 - 40H - 40" (1m) Probe, 2190°F (1200°C) max, with 10' (3m) HEATED Hose and HEATED Probe Head (AASR04)
- S9000 - AARC10 - Non-Fading Paper Roll (pack of 10)
- S9000 - AAFS02 - Sintered Filter with Support for probe
- S9000 - AAFS01 - Replacement Inox filter for AASF02
- S9000 - AATTA03 - 36" (900mm) Pitot Tube for Gas Velocity Measurements
- S9000 - AACEX02S - 10' (3m) Dual Hose Extension
- S9000 - WFILA0001 - Particulate Filter (Internal)
- S9000 - WFILX0016 - Particulate Filter (External)
- S9000 - AAFA04 - Anti-Dust Filter (2 pcs), only with NH3 installed
- S9000 - AASP01 - Heat Protection Shield for probes
- S9000 - AAEB01 - Trunk Extension
- S9000 - AATY01 - Trunk Trolley
- S9000 - AACSA04 - 4" (100mm) Auxiliary Temperature Probe w/ 10ft (3m) hose
| Model | S9000 |
|---|
L’analizzatore portatile di emissioni Seitron S9000 misura fino a 12 gas con 9 sensori singoli e un banco NDIR per CO alto, CO2 diretto e idrocarburi. Rileva O2 fino al 25% in volume e CxHy fino al 5%, con stampante integrata, display a colori e connettività Bluetooth.
Perfetto per bruciatori industriali, cogenerazione, turbine a gas, forni e laboratori, il S9000 consente monitoraggi prolungati. Disponibile con raffreddatore, sonda riscaldata, registrazione in tempo reale e memoria per 16.000 test.
Testwall può fornire il Seitron S9000 usato, completamente testato. Con supporto esperto e consegna globale, Testwall garantisce strumentazione ad alte prestazioni con massima affidabilità. Contattaci per taratura o riparazione del Seitron S9000.