Sorensen
Sorensen SGA600-8
DC Power Supply, 600V, 8A, 5kW
600 V Tensione di Uscita
8 A Corrente di Uscita
5000 W Potenza Massima
Alimentatore DC Programmabile Tipo di Alimentazione
GPIB, RS-232 Interfaccia di Programmazione

| Attributo | Valore |
|---|---|
| Tensione di Uscita | 600 V |
| Corrente di Uscita | 8 A |
| Potenza Massima | 5000 W |
| Tipo di Alimentazione | Alimentatore DC Programmabile |
| Interfaccia di Programmazione | GPIB, RS-232 |
| Regolazione della Tensione | 0 - 600 V |
| Regolazione della Corrente | 0 - 8 A |
| Tensione di Ingresso | 208/240 V AC, Trifase |
| Dimensioni (L x A x P) | 483 x 133 x 660 mm |
| Peso | Circa 34 kg |
| Model | SGA600-8 |
|---|
Sorensen SGA600-50 (call for availability)
The Sorensen SGA600-50 is a Programmable Precision High Power DC Power Supply that provides front panel analog controls as well as essential features like 10-turn potentiometers for setting voltage and cur, 3½ digit LED readout plus front panel over-voltage protection (OVP) preview/adjustment and reset.Features of the Sorensen SGA600-50 include:
High Power Density: 30kW in a 6U chassis Wide Voltage Range: 0-600V and 0-50 Amps Fast Load Transient Response: Protection from undesired voltage excursions Low RMS and P-P Noise: Suitable for the most sensitive applications Parallelable up to 150 kW: Expandable as your requirement grows Modular Design: Upgradeable for the ultimate in investment protection Display: 3½ digits Resolution: Optional IEEE-488.2 + RS-232C + Ethernet provides precise control Ethernet Control: Optional LXI Class C compliant communication through integrated web server Direct Relay Control: Control output and sense isolation relays, along with polarity relays. (Ethernet Option Only) Hardware Trigger: Ethernet Option Only Specifications of the Sorensen SGA600-50 include:
Common:
Remote Sense: Load-line loss compensation for models <= 100 V is 10% above full scale voltage total (5% per load-line), and models > 100 V is 4% above full scale voltage total (2% per load-line). Parallel Operation: Up to 5 units may be paralleled for additional cur within the power supply single-unit specifications, with exception of the DC output cur set accuracy. Additional paralleled SG units will add 0.3% inaccuracy per unit. To parallel more than 5 units,contact factory. Series Operation: Up to 2 units (see Output Float Voltage) Input:
Nominal Voltage 3 phase, 3 wire + ground: 208/220 VAC (operating range 187 - 242 VAC); 380/400 VAC (operating range 342 - 440 VAC); and 440/480 VAC (operating range 396 - 528 VAC) Frequency: 47 – 63Hz (optional 400Hz @ 208VAC, does not carry CE, UL or CSA markings) Power Factor: >0.9 typical at 208/220 VAC input; >0.78 typical at 380/400 VAC input; and >0.69 typical at 440/480 VAC input Protection (typical): ½ cycle ride-though on all three phases, 3 cycle ride through on single phase; missing phase shutdown (800V model 6.4 msec on all 3 phases) Environmental:
Operating Temperature: 0 to 50º C Storage Temperature: -25º C to 65º C Humidity Range: Relative humidity up to 95% non-condensing, 0º C – 50º C Altitude: Operating full power available up to 5,000 ft. (~1,500 m), derate 10% of full power for every 1,000 feet higher; non-operating to 40,000 ft. (~12,000 m) Cooling: Front and side air inlet, rear exhaust. Temperature controlled, variable speed fans. Units may be stacked without spacing. Regulatory: Certified to UL/CSA 61010 and IEC/EN 61010-1, CE Compliant, Semi-F47 Compliant Front Panel Dust Filter: 30 PPI (Pores Per Inch) - must ensure adequate airflow and / or derate max. temperature. 3U unit only. Physical:
Dimensions: Width: 19.00” (48.3 cm), Depth 25.0” (63.5 cm) Height: 5-15 kW units: 3U – 5.25” rack mount (13.34 cm) 20-30 kW units: 6U – 10.5” rack mount (26.67 cm) Weight: 3U < 80 lbs. (36 kg) 6U Output:
Ripple & Noise (Voltage Mode, Typical): Ripple and noise specified at full load, nominal AC input. Noise measured with 6ft. cable, 1µf at load Ripple (Cur Mode): <+/- 0.04% of full scale rms cur DC Voltage Slew Rate: 45A / ms typical - resistive load Line Regulation (with sense wires used): (±10% of nominal AC input, constant load); Voltage Mode: +/- 0.01% of full scale; and Cur Mode: +/- 0.05% of full scale Load Regulation (with sense wires used): no load to full load, nominal AC input); Voltage Mode: +/- 0.02% of full scale; and Cur Mode: +/- 0.1% of full scale Load Transient Response: Recovers within 1ms to +/-0.75% of full-scale of steadystate output for a 50% to 100% or 100% to 50% load change Efficiency: 87% typical at nominal line and max load Stability: ±0.05% of set point after 30 minute warm-up and over 8 hours at fixed line, load and temperature Temperature Coefficient: 0.02%/ C of maximum output voltage rating for voltage set point 0.03%/ C of maximum output cur rating for cur set point Output Float Voltage: Negative terminal within +/- 300 V of chassis potential. (We recommend the use of optional isolated analog Interface (IAI).) Supplies in “series” should be the same output voltage/cur. Programming Specifications of the Sorensen SGA600-50 include:
Front Panel Display:Voltage Accuracy: +/- 0.1% of full scale Cur Accuracy: +/- 0.4% of full scale Resolution: 3½ digits Remote Analog Interface:
Voltage Accuracy: +/-0.25% of full scale for 0-5 V range, +/-0.5% of fullscale for 0-10 V range Cur Accuracy: 0.8% of full scale Remote Digital Interface:
Voltage Accuracy: +/- 0.1% of full scale Cur Accuracy: +/- 0.4% of full scale Resolution: +/-0.002% of full scale OVP:
Accuracy: +/- 1% of full scale Resolution: +/-0.002% of full scale User I/O:
Disconnect & Polarity-reversal relay control (Only available with Ethernet Option) Read-Back / Monitoring Specifications of the Sorensen SGA600-50 include:
Front Panel Display:Voltage Accuracy: +/- 0.1% of full scale Cur Accuracy: +/- 0.4% of full scale Resolution: 3½ digits Remote Analog Interface:
Accuracy: +/-1.0% of full scale (0 - 10V) Remote Digital Interface:
Voltage Accuracy: +/- 0.1% of full scale Cur Accuracy: +/- 0.4% of full scale Resolution: +/-0.002% of full scale User I/O:
Disconnect & Polarity-reversal relay control (Only available with Ethernet Option)
The Sorensen SGA600-8 is a Programmable Precision High Power DC Power Supply that provides front panel analog controls as well as essential features like 10-turn potentiometers for setting voltage and cur, 3½ digit LED readout plus front panel over-voltage protection (OVP) preview/adjustment and reset.
Features of the Sorensen SGA600-8 include:
High Power Density: 5kW in a 3U chassis Wide Voltage Range: 0-600V and 0-8 Amps Fast Load Transient Response: Protection from undesired voltage excursions Low RMS and P-P Noise: Suitable for the most sensitive applications Parallelable up to 150 kW: Expandable as your requirement grows Modular Design: Upgradeable for the ultimate in investment protection Display: 3½ digits Resolution: Optional IEEE-488.2 + RS-232C + Ethernet provides precise control Ethernet Control: Optional LXI Class C compliant communication through integrated web server Direct Relay Control: Control output and sense isolation relays, along with polarity relays. (Ethernet Option Only) Hardware Trigger: Ethernet Option Only Specifications of the Sorensen SGA600-8 include:
Common:Remote Sense: Load-line loss compensation for models <= 100 V is 10% above full scale voltage total (5% per load-line), and models > 100 V is 4% above full scale voltage total (2% per load-line). Parallel Operation: Up to 5 units may be paralleled for additional cur within the power supply single-unit specifications, with exception of the DC output cur set accuracy. Additional paralleled SG units will add 0.3% inaccuracy per unit. To parallel more than 5 units,contact factory. Series Operation: Up to 2 units (see Output Float Voltage) Input: Nominal Voltage 3 phase, 3 wire + ground: 208/220 VAC (operating range 187 - 242 VAC); 380/400 VAC (operating range 342 - 440 VAC); and 440/480 VAC (operating range 396 - 528 VAC) Frequency: 47 – 63Hz (optional 400Hz @ 208VAC, does not carry CE, UL or CSA markings) Power Factor: >0.9 typical at 208/220 VAC input; >0.78 typical at 380/400 VAC input; and >0.69 typical at 440/480 VAC input Protection (typical): ½ cycle ride-though on all three phases, 3 cycle ride through on single phase; missing phase shutdown (800V model 6.4 msec on all 3 phases) Environmental: Operating Temperature: 0 to 50º C Storage Temperature: -25º C to 65º C Humidity Range: Relative humidity up to 95% non-condensing, 0º C – 50º C Altitude: Operating full power available up to 5,000 ft. (~1,500 m), derate 10% of full power for every 1,000 feet higher; non-operating to 40,000 ft. (~12,000 m) Cooling: Front and side air inlet, rear exhaust. Temperature controlled, variable speed fans. Units may be stacked without spacing. Regulatory: Certified to UL/CSA 61010 and IEC/EN 61010-1, CE Compliant, Semi-F47 Compliant Front Panel Dust Filter: 30 PPI (Pores Per Inch) - must ensure adequate airflow and / or derate max. temperature. 3U unit only. Physical: Dimensions: Width: 19.00” (48.3 cm), Depth 25.0” (63.5 cm) Height: 5-15 kW units: 3U – 5.25” rack mount (13.34 cm) 20-30 kW units: 6U – 10.5” rack mount (26.67 cm) Weight: 3U < 80 lbs. (36 kg) 6U Output: Ripple & Noise (Voltage Mode, Typical): Ripple and noise specified at full load, nominal AC input. Noise measured with 6ft. cable, 1µf at load Ripple (Cur Mode): <+/- 0.04% of full scale rms cur DC Voltage Slew Rate: 45A / ms typical - resistive load Line Regulation (with sense wires used): (±10% of nominal AC input, constant load); Voltage Mode: +/- 0.01% of full scale; and Cur Mode: +/- 0.05% of full scale Load Regulation (with sense wires used): no load to full load, nominal AC input); Voltage Mode: +/- 0.02% of full scale; and Cur Mode: +/- 0.1% of full scale Load Transient Response: Recovers within 1ms to +/-0.75% of full-scale of steadystate output for a 50% to 100% or 100% to 50% load change Efficiency: 87% typical at nominal line and max load Stability: ±0.05% of set point after 30 minute warm-up and over 8 hours at fixed line, load and temperature Temperature Coefficient: 0.02%/ C of maximum output voltage rating for voltage set point 0.03%/ C of maximum output cur rating for cur set point Output Float Voltage: Negative terminal within +/- 300 V of chassis potential. (We recommend the use of optional isolated analog Interface (IAI).) Supplies in “series” should be the same output voltage/cur. Programming Specifications of the Sorensen SGA600-8 include:
Front Panel Display:Voltage Accuracy: +/- 0.1% of full scale Cur Accuracy: +/- 0.4% of full scale Resolution: 3½ digits Remote Analog Interface:
Voltage Accuracy: +/-0.25% of full scale for 0-5 V range, +/-0.5% of fullscale for 0-10 V range Cur Accuracy: 0.8% of full scale Remote Digital Interface: Voltage Accuracy: +/- 0.1% of full scale Cur Accuracy: +/- 0.4% of full scale Resolution: +/-0.002% of full scale OVP: Accuracy: +/- 1% of full scale Resolution: +/-0.002% of full scale User I/O: Disconnect & Polarity-reversal relay control (Only available with Ethernet Option) Read-Back / Monitoring Specifications of the Sorensen SGA600-8 include:
Front Panel Display:Voltage Accuracy: +/- 0.1% of full scale Cur Accuracy: +/- 0.4% of full scale Resolution: 3½ digits Remote Analog Interface:
Accuracy: +/-1.0% of full scale (0 - 10V) Remote Digital Interface: Voltage Accuracy: +/- 0.1% of full scale Cur Accuracy: +/- 0.4% of full scale Resolution: +/-0.002% of full scale User I/O: Disconnect & Polarity-reversal relay control (Only available with Ethernet Option)
The Sorensen SGA600-50 is a Programmable Precision High Power DC Power Supply that provides front panel analog controls as well as essential features like 10-turn potentiometers for setting voltage and cur, 3½ digit LED readout plus front panel over-voltage protection (OVP) preview/adjustment and reset.Features of the Sorensen SGA600-50 include:
Common:
Front Panel Display:
Front Panel Display:
Product Overview
Sorensen SGA600-8 (call for availability)
The Sorensen SGA600-8 is a Programmable Precision High Power DC Power Supply that provides front panel analog controls as well as essential features like 10-turn potentiometers for setting voltage and cur, 3½ digit LED readout plus front panel over-voltage protection (OVP) preview/adjustment and reset.
Features of the Sorensen SGA600-8 include:
Common:
Front Panel Display:
Front Panel Display:




