Manufacturer Logo
Tektronix

Tektronix TDS700D

fino a 2 GHz Larghezza di banda
fino a 4 GS/s in tempo reale Frequenza di campionamento
4 canali Numero di canali
fino a 500.000 punti per canale Lunghezza del record
8 bit Risoluzione verticale
Richiedi scheda tecnica
Attributo Valore
Larghezza di banda fino a 2 GHz
Frequenza di campionamento fino a 4 GS/s in tempo reale
Numero di canali 4 canali
Lunghezza del record fino a 500.000 punti per canale
Risoluzione verticale 8 bit
Sensibilità verticale da 1 mV/div a 10 V/div
Base dei tempi da 200 ps/div a 40 s/div
Interfacce di connettività GPIB, RS-232, Centronics
Display Display a colori da 10,2 cm (4 pollici)
Alimentazione 100-240 V CA, 50/60 Hz
Tektronix TDS700D Options:
  • TDS700D - Opt. 05 - Add video trigger (NTSC, PAL, HDTV, FlexFormat™). (Not available on the TDS794D)
  • TDS700D - Opt. 1M - Add 130 K/channel memory length (500 K max on TDS794D, TDS784D, TDS754D; 250 K max on TDS724D)
  • TDS700D - Opt. 2M - Add 2 M/channel memory length (8 M max on TDS794D, TDS784D, TDS754D; 4 M max on TDS724D). Includes internal hard disk drive
  • TDS700D - Opt. 2C - Communication Signal Analyzer; includes comm triggers and communication mask testing
  • TDS700D - Opt. 3C - Short-wavelength (Fibre Channel FC133, FC266, FC513, FC1063) Optical Reference Receiver; includes P6701B and system calibration (Not Available on the TDS794D)
  • TDS700D - Opt. 4C - Long-wavelength (SONET/SDH OC1/STM0, OC3/STM1, OC12/STM4) Optical Reference Receiver; includes P6703B and system calibration (Not Available on the TDS794D)
  • TDS794D - Opt. 31 - Add 1 each P6339A buffered passive probe (TDS794D only)
  • TDS700D - Opt. 33 - Add 1 each P6158 low capacitance probe (TDS794D, TDS784D only)
  • TDS700D - Opt. 34 - Add 1 each P6247 differential probe
  • TDS700D - Opt. 35 - Add 1 each P6243 active probe (TDS754D, TDS724D only)
  • TDS700D - Opt. 36 - Add 1 each P6139A passive probe (TDS784D, TDS754D, TDS724D only)
  • TDS784D - Opt. 37 - Add 1 each P6245 active probe (TDS784D only)
  • TDS794D - Opt. 38 - Add 1 each P6249 4 GHz active probe (TDS794D only)
  • TDS794D - Opt. 39 - Add 1 each P6248 1.7 GHz differential probe (TDS794D only)
  • TDS724D - Opt. 2D - Delete 2 each standard probes (TDS724D only)
  • TDS754D - Opt. 4D - Delete 4 each standard probes (TDS754D only)
  • TDS700D - Opt. A1 - European power cord (220 V, 50 Hz)
  • TDS700D - Opt. A2 - UK power cord (240 V, 50 Hz)
  • TDS700D - Opt. A3 - Australian power cord (240 V, 50 Hz)
  • TDS700D - Opt. A4 - North American power cord (240 V, 60 Hz)
  • TDS700D - Opt. A5 - Swiss power cord (220 V, 50 Hz)
  • TDS700D - Opt. 1K - Add K420 scope cart
  • TDS700D - Opt. 1R - Rackmount kit
  • TDS700D - Opt. L1 - Substitute French user manual for English user manual
  • TDS700D - Opt. L3 - Substitute German user manual for English user manual
  • TDS700D - Opt. L5 - Substitute Japanese user manual for English user manual
  • TDS700D - Opt. L9 - Substitute Korean user manual for English user manual
  • TDS700D - Opt. C3 - Three years of Calibration Services
  • TDS700D - Opt. D1 - Cal Data Report
  • TDS700D - Opt. D3 - Test Data (requires Opt. C3)
Modulo di calibrazione Tektronix TDS700D

Modulo di riparazione Tektronix TDS700D
Maximum file size: 40MB

No Related Posts

Ulteriori informazioni
ModelTDS700D

L’oscilloscopio digitale a fosfori Tektronix TDS700D offre una larghezza di banda da 500 MHz a 2 GHz, campionamento a 4 GS/s e acquisizione fino a 200.000 wfs/s per analisi ad alta fedeltà.

Supporta lunghezze di registrazione fino a 8M punti, modalità Hi-Res, precisione ±1% e funzioni avanzate di trigger.

Testwall può fornire il Tektronix TDS700D usato, completamente testato. Con supporto esperto e consegna globale, Testwall garantisce strumenti ad alte prestazioni con affidabilità e qualità del servizio senza pari. Contattaci se necessiti di calibrazione o riparazione del Tektronix TDS700D.

Clicky Copyright © 2013-present Magento, Inc. All rights reserved.