Manufacturer Logo
Tektronix

Tektronix TIVM02

Differential Probe, 200 MHz, 5X/50X, 3M Cable
500 MHz Larghezza di banda
1000 V CAT III / 600 V CAT IV Tensione massima di ingresso
10:1 / 100:1 Rapporto di attenuazione
10 MΩ Impedenza di ingresso
12 pF Capacità di ingresso
Richiedi scheda tecnica
Attributo Valore
Larghezza di banda 500 MHz
Tensione massima di ingresso 1000 V CAT III / 600 V CAT IV
Rapporto di attenuazione 10:1 / 100:1
Impedenza di ingresso 10 MΩ
Capacità di ingresso 12 pF
Lunghezza del cavo 1,3 m
Temperatura di esercizio 0°C – 50°C
Compatibilità oscilloscopio Oscilloscopi Tektronix serie MSO/DPO
Certificazioni di sicurezza UL, CE, CSA
Tipo di connettore BNC
Tektronix TIVM02 Options:
  • TIVM02 - C3 - Calibration Service 3 Years
  • TIVM02 - C5 - Calibration Service 5 Years
  • TIVM02 - D1 - Calibration Data Report
  • TIVM02 - D3 - Calibration Data Report 3 Years (with Opt. C3)
  • TIVM02 - D5 - Calibration Data Report 5 Years (with Opt. C5)
  • TIVM02 - G3 - Complete Care 3 Years (includes loaner, scheduled calibration, and more)
  • TIVM02 - R3 - Repair Service 3 Years (including warranty)
  • TIVM02 - R5 - Repair Service 5 Years (including warranty)
Modulo di calibrazione Tektronix TIVM02

Modulo di riparazione Tektronix TIVM02
Maximum file size: 40MB

No Related Posts

Ulteriori informazioni
ModelTIVM02

 TEKTRONIX TIVM02 Differential Probe

 

The Tektronix TIVM02 IsoVu Measurement System offers a galvanically isolated measurement solution for accurately resolving high bandwidth, differential signals up to ±50 Vpk in the presence of large common mode voltages with the best in class common mode rejection performance across its bandwidth.  The Tektronix TIVM02 (IsoVu) products can be used on most Tektronix oscilloscopes with the TekVPI interface and on MSO/DPO70K series oscilloscopes with the TCA-VPI50 adapter. IsoVu utilizes an electro-optic sensor that converts the electrical signal from the sensor tip cables to an optical signal, which electrically isolates the device-under-test from the oscilloscope.

IsoVu incorporates four separate lasers, an optical sensor, five optical fibers, and sophisticated feedback and control techniques. The sensor head, which connects to the test point, has complete electrical isolation and is powered over one of the optical fibers (No batteries required). IsoVu is an ideal solution for users making the following measurements:

Differential measurements in the following conditions:

  • Complete galvanic isolation is required
  • High common mode voltage
  • High frequency common mode interference
  • High frequency measurements
  • Measurements in high EMI environments
  • EMI compliance testing
  • ESD testing

 

Specifications for the  TEKTRONIX TIVM02 Differential Probe Include:

Bandwidth 200 MHz
Rise Time ‰¤ 1.8 ns (typical)
Attenuation up to 50X
Common mode voltage 60 kV peak

 

Clicky Copyright © 2013-present Magento, Inc. All rights reserved.