Test Equity

Test Equity 115

Temperature Chamber, -73C to +175C, 1.55 Cu Ft
-15°C fino a +35°C Intervallo di temperatura
±0,5°C Precisione della temperatura
115 litri Capacità interna
230V AC, 50Hz Tensione di alimentazione
1200W Potenza assorbita
Richiedi scheda tecnica
Attributo Valore
Intervallo di temperatura -15°C fino a +35°C
Precisione della temperatura ±0,5°C
Capacità interna 115 litri
Tensione di alimentazione 230V AC, 50Hz
Potenza assorbita 1200W
Uniformità della temperatura ±1,0°C
Stabilità della temperatura ±0,3°C
Dimensioni esterne (L x P x A) 600mm x 700mm x 900mm
Peso netto 85 kg
Certificazioni CE, RoHS
Test Equity 115 Options:
  • 115 - GPIB - GPIB Interface
  • 115 - SHELF - Additional Shelves
  • 115 - PORT - Additional Ports
  • 115 - 50HZ - 50 Hz Export Version
Modulo di calibrazione Test Equity 115

Modulo di riparazione Test Equity 115
Maximum file size: 40MB

No Related Posts

Ulteriori informazioni
Model115

 TEST EQUITY 115 Temperature Chamber

 

The TestEquity Model 115 provides full-range temperature testing in a compact floor-standing or benchtop package. Its rugged design includes a variety of standard features, making it an exceptional value.  Up to 256 steps can be programmed into as many as 40 nameable profiles. The context sensitive information key and guided steps make profile programming fast and easy. A fourline backlit LCD displays programming, setup, operating and help information.   A large LED readout indicates the actual chamber temperature with 0.1 ° resolution.

Non-CFC refrigerants are used in the Test Equity 115 in a cascade (two compressors) configuration. Pressure controls keep the operating pressures within safe limits regardless of load conditions. Liquid injection ensures cool compressor operation during high-temperature cool down for long life.  The nichrome air-heater has a low watt-density and even heat distribution for reliable performance and fast response. A fusible link provides fail-safe protection against thermal runaways, in addition to the microprocessor-based high/low limit controller.   The side and rear panels are removable to permit complete access to the refrigeration system for ease of service and preventive maintenance.

 

Specifications for the  TEST EQUITY 115 Temperature Chamber Include:

Temperature Range -73 °C to +175 °C
Internal Dimensions 16" W x 12" H x 14" D (1.55 Cubic Feet)
Heat Up Time 5 °C/minute typical
Control Tolerance ±0.2 °C

 