Manufacturer Logo
Kaelus

Kaelus iPA-0600D

Battery-portable 40 W PIM analyser, 600 MHz band, 7-16 DIN
600 MHz Frequency Band
TX1 617-630 MHz, TX2 640-652 MHz Transmit (TX)
663-698 MHz Receive (PIM)
0.1 to 40 W per tone (+20 to +46 dBm, 1 dB steps), ±0.5 dB Output Power
3rd, 5th, 7th and 9th order, reverse (reflected) IM Orders
Attribute Value
Frequency Band 600 MHz
Transmit (TX) TX1 617-630 MHz, TX2 640-652 MHz
Receive (PIM) 663-698 MHz
Output Power 0.1 to 40 W per tone (+20 to +46 dBm, 1 dB steps), ±0.5 dB
IM Orders 3rd, 5th, 7th and 9th order, reverse (reflected)
RF Port 7-16 DIN female
Display / Control Touch screen; Wi-Fi remote control
Battery 25.9 V Li-ion, removable
Range to Fault Compatible with Kaelus RTF module
Kaelus iPA-0600D Options:
  • RTF module - Range to Fault module: distance to PIM and return loss faults (sold separately)
  • Dual battery charger - Standalone charger for spare battery packs
  • Hard case - Optional hard case giving IP67 protection when enclosed
  • iAK-0060A - Portable PIM accessory kit
Calibration Form Kaelus iPA-0600D

Repair Form Kaelus iPA-0600D
Maximum file size: 40MB

The Kaelus iPA-0600D is a battery-powered passive intermodulation (PIM) analyser for the 600 MHz band, with 0.1 to 40 W per tone. It is built for tower-top, tower-base, rooftop and in-building DAS testing and measures reverse (reflected) 3rd, 5th, 7th and 9th order PIM.

Operating modes include spectrum monitor, PIM-versus-frequency sweep and PIM-versus-time trace, with on-instrument reporting and local touch-screen or remote Wi-Fi control. It is compatible with the optional Kaelus RTF Range to Fault module for locating PIM and return loss faults.

Testwall can supply the used Kaelus iPA-0600D, fully tested, with a 12-month warranty and delivery across Europe. Calibration can be arranged on request before shipping. Please contact us if you need calibration or repair of the Kaelus iPA-0600D.