Kaelus iPA-1921A

| Attribute | Value |
|---|---|
| Frequency Band | PCS/AWS dual-band |
| Transmit (TX) | PCS: TX1 1930-1950 MHz, TX2 1970-1990 MHz; AWS: TX1 1930-1950 MHz, TX2 2110-2155 MHz |
| Receive (PIM) | 1850-1910 / 1710-1755 MHz |
| Output Power | 0.1 to 20 W per tone (+20 to +43 dBm, 1 dB steps), ±0.5 dB |
| IM Orders | 3rd, 5th, 7th and 9th order, reverse (reflected) |
| Residual PIM | < -117 dBm / -160 dBc max (< -125 dBm / -168 dBc typ.) at 2 x 20 W |
| RF Port | 7-16 DIN female |
| Display / Control | 4.3 in touch screen; Wi-Fi remote control via web browser |
| Battery | 25.9 V Li-ion, removable |
| Environmental | -10 to +45 °C operating; IP54 (IP67 in optional hard case) |
| Dimensions / Weight | 369 x 160 x 240 mm (H x D x W); 12 kg |
Kaelus iPA-1921A Options:
- RTF module - Range to Fault module: distance to PIM and return loss faults (sold separately)
- Dual battery charger - Standalone charger for spare battery packs
- Hard case - Optional hard case giving IP67 protection when enclosed
- iAK-0060A - Portable PIM accessory kit
The Kaelus iPA-1921A is a battery-powered passive intermodulation (PIM) analyser for the PCS/AWS dual-band band, with 0.1 to 20 W per tone. It is built for tower-top, tower-base, rooftop and in-building DAS testing and measures reverse (reflected) 3rd, 5th, 7th and 9th order PIM.
Operating modes include spectrum monitor, PIM-versus-frequency sweep and PIM-versus-time trace, with on-instrument reporting and local touch-screen or remote Wi-Fi control. It is compatible with the optional Kaelus RTF Range to Fault module for locating PIM and return loss faults.
Testwall can supply the used Kaelus iPA-1921A, fully tested, with a 12-month warranty and delivery across Europe. Calibration can be arranged on request before shipping. Please contact us if you need calibration or repair of the Kaelus iPA-1921A.