Keithley

Keithley 2182

Nanovoltmeter, 2 Ch.
DC Voltage Nanovoltmeter Measurement Function
10 nV to 120 V Voltage Measurement Range
10 nV (on 10 mV range) Voltage Measurement Resolution
2 Channels Number of Input Channels
Greater than 10 GΩ Input Impedance
Request datasheet
Attribute Value
Measurement Function DC Voltage Nanovoltmeter
Voltage Measurement Range 10 nV to 120 V
Voltage Measurement Resolution 10 nV (on 10 mV range)
Number of Input Channels 2 Channels
Input Impedance Greater than 10 GΩ
Accuracy (1 Year, 23°C ± 5°C) ±(35 ppm of reading + 6 ppm of range) on 10 mV range
Normal Mode Rejection (NMR) 60 dB at 50/60 Hz
Common Mode Rejection (CMR) 120 dB at DC, 50/60 Hz
Interface / Connectivity IEEE-488 (GPIB) and RS-232
Operating Temperature Range 0°C to 50°C
Keithley 2182 Options:
  • 2182 - 2107-30 - Low Thermal Input Cable with spade lugs, 9.1 m (30 ft)
  • 2182 - 2182-KIT - Low Thermal Connector with strain relief
  • 2182 - 2187-4 - Low Thermal Test Lead Kit
  • 2182 - 2188 - Low Thermal Calibration Shorting Plug
  • 2182 - 4288-1 - Single Fixed Rack Mount Kit
  • 2182 - 4288-2 - Dual Fixed Rack Mount Kit
  • 2182 - 7007-1 - Shielded GPIB Cable, 1 m (3.2 ft)
  • 2182 - 7007-2 - Shielded GPIB Cable, 2 m (6.5 ft)
  • 2182 - 7009-5 - Shielded RS-232 Cable 1.5 m (5 ft)
  • 2182 - 8501-1 - Trigger-Link Cable 1 m (3.2 ft)
  • 2182 - 8501-2 - Trigger-Link Cable 2 m (6.5 ft)
  • 2182 - 8503 - Trigger-Link Cable to 2 Male BNC Connectors
Calibration Form Keithley 2182

Repair Form Keithley 2182
Maximum file size: 40MB

No Related Posts

More Information
Model2182

The Keithley 2182 Nanovoltmeter delivers dual‑channel ultra‑low voltage precision, achieving as little as 15 nV p-p noise at 1 s and 40–50 nV p-p at 60 ms, with advanced Delta mode, built‑in thermocouple linearization, and selectable speed/noise filters—ideal for metrology, nanotech, and materials research.

Engineered for comparing voltage standards, characterizing low‑resistance materials, and analyzing superconductors, it integrates seamlessly with current sources like the Keithley 622X or Series 2400 for high‑accuracy resistance measurements.

Testwall can supply the used Keithley 2182, fully tested. With expert support and global delivery, Testwall ensures high‑performance instrumentation with unmatched reliability and service quality. Please contact us directly if you need calibration or repair of the Keithley 2182.

Clicky Copyright © 2025-present Magento, Inc. All rights reserved.