Keysight (Agilent)
Keysight (Agilent) 8722ES
40GHz Vector Network Analyser
50 MHz to 40 GHz Frequency Range
2-Port S-Parameter Network Analyzer Number of Ports
Up to 100 dB Dynamic Range
-10 dBm to +10 dBm Output Power Range
S11, S21, S12, S22 (Full 2-Port S-Parameters) Measurement Parameters

| Attribute | Value |
|---|---|
| Frequency Range | 50 MHz to 40 GHz |
| Number of Ports | 2-Port S-Parameter Network Analyzer |
| Dynamic Range | Up to 100 dB |
| Output Power Range | -10 dBm to +10 dBm |
| Measurement Parameters | S11, S21, S12, S22 (Full 2-Port S-Parameters) |
| Connector Type | 2.4 mm (female) RF connectors |
| IF Bandwidth | 10 Hz to 3 kHz (selectable) |
| Number of Data Points | 3 to 1601 points per sweep |
| Display | 10.4-inch color CRT display |
| Interface/Connectivity | GPIB (IEEE-488), RS-232, parallel printer port |
Keysight Technologies 8722ES Options:
- 8722ES - 007 - Mechanical transfer switch (replaces solid-state transfer switch to provide higher output power)
- 8722ES - 012 - Direct-access receiver configuration (front panel access to A and B samplers for improved receiver sensitivity)
- 8722ES - 085 - High-power system (internally controlled 0 to 55 dB step attenuators, RF loops for amplifier insertion, capable of full two-port calibrated measurements to 20 watts)
- 8722ES - 089 - Frequency offset mode (allows receiver to be offset from source frequency for direct conversion loss measurement of mixers)
- 8722ES - 400 - Fourth sampler and TRL calibration firmware (converts built-in test set to four-sampler configuration for TRL calibration)
- 8722ES - 010 - Time-domain (converts frequency domain data to time domain using Fourier transformation technique)
- 8722ES - 1D5 - High-stability frequency reference (±0.05 ppm temperature stability from 0 to 60°C)
| Model | 8722ES |
|---|
The Keysight (Agilent) 8722ES Network Analyzer is a fully integrated solution combining a synthesized source, S-parameter test set, and tuned receiver for complete vector network analysis. Operating from 50 MHz to 40 GHz, it supports full two-port magnitude and phase measurements in both forward and reverse directions. Advanced vector accuracy enhancements include adapter-removal techniques, TRL calibration (optional), and full two-port error correction.
Designed for demanding RF and microwave applications, the 8722ES features two independent measurement channels and four display channels. It supports frequency and power sweeps, fast sweep and data transfer rates, and includes options for time-domain analysis (010), a 4-sampler test set (400), and a high-stability frequency reference (1D5). Additional features include pass/fail testing, electronic calibration (ECal), and internal automation with test sequencing.
Testwall can supply the used Keysight (Agilent) 8722ES, fully tested. With expert support and global delivery, Testwall ensures high-performance instrumentation with unmatched reliability and service quality. Please contact us directly if you need calibration or repair of the Keysight (Agilent) 8722ES.