NH Research

NH Research 4600-18

AC Electronic Load, 350V, 108A, 18kW
0 – 18 V Output Voltage Range
0 – 220 A Output Current Range
4000 W Output Power
208/240 VAC, Single Phase Input Voltage
47 – 63 Hz Input Frequency
Request datasheet
Attribute Value
Output Voltage Range 0 – 18 V
Output Current Range 0 – 220 A
Output Power 4000 W
Input Voltage 208/240 VAC, Single Phase
Input Frequency 47 – 63 Hz
Regulation (Voltage) 0.05% + 5 mV
Regulation (Current) 0.1% + 20 mA
Ripple & Noise (Voltage) 50 mV RMS
Programming Interface Analog / IEEE-488 (GPIB) / RS-232
Operating Temperature 0°C to 50°C
Calibration Form NH Research 4600-18

Repair Form NH Research 4600-18
Maximum file size: 40MB

No Related Posts

More Information
Model4600-18

The NH Research 4600-18 AC Electronic Load delivers 18kW power with a maximum current of 180A and a voltage range of 50–350V. It supports 7 emulation modes for linear and non-linear AC loading with full control of power factor and crest factor. Integrated precision ranging eliminates the need for external instruments, offering high-resolution measurements of frequency, voltage, current, and power.

Ideal for testing UPS systems, AC sources, inverters, switches, circuit breakers, fuses, and connectors, the 4600-18 ensures versatile and accurate performance under diverse operating conditions. It includes user-defined waveform control and a PC softpanel for complete management.

Testwall can supply the used NH Research 4600-18 AC Electronic Load, fully tested. With expert support and global delivery, Testwall ensures high-performance instrumentation with unmatched reliability and service quality. Please contact us directly if you need calibration or repair of the NH Research 4600-18 AC Electronic Load.