NH Research 4760-24

| Attribute | Value |
|---|---|
| Output Voltage Range | 0 – 24 V |
| Output Current Range | 0 – 100 A |
| Output Power | 2400 W |
| Input Voltage | 208/240 VAC, Single Phase |
| Input Frequency | 47 – 63 Hz |
| Regulation (Voltage) | 0.05% + 5 mV |
| Regulation (Current) | 0.1% + 10 mA |
| Ripple and Noise (Voltage) | 10 mV RMS typical |
| Programming Interface | Analog, RS-232, GPIB (IEEE-488) |
| Operating Temperature | 0°C to 50°C |
| Model | 4760-24 |
|---|
The NH Research 4760-24 LXI Series Electronic Load is designed for high-power and high-voltage applications, ideal for fuel cell, power conversion, telecom rectifier, and Vehicle-to-Grid (V2G) testing. It features Auto Mode for seamless, glitch-free switching between CR, CC, CV, and CP, ensuring precise and reliable measurements.
With a 100-step macro-recording function, complex dynamic load sequences can be captured and replayed for accurate testing scenarios. Its modular, synchronously controlled, and power-balanced architecture enables efficient parallel operation.
Testwall can supply the used NH Research 4760-24, fully tested. With expert support and global delivery, Testwall ensures high-performance instrumentation with unmatched reliability and service quality. Please contact us directly if you need calibration or repair of the NH Research 4760-24.