NH Research

NH Research 9410-12

Grid Simulator, 12kW, 24kVA
0 – 600 V DC Output Voltage Range
0 – 12 A Output Current Range
7200 W (7.2 kW) Output Power
208 V AC, Three-Phase Input Voltage
47 – 63 Hz Input Frequency
Request datasheet
Attribute Value
Output Voltage Range 0 – 600 V DC
Output Current Range 0 – 12 A
Output Power 7200 W (7.2 kW)
Input Voltage 208 V AC, Three-Phase
Input Frequency 47 – 63 Hz
Regulation Mode Constant Voltage (CV) / Constant Current (CC)
Programming Interface IEEE-488 (GPIB) / RS-232
Output Voltage Accuracy ±0.1% of Full Scale
Output Current Accuracy ±0.1% of Full Scale
Cooling Method Forced Air Cooling
NH Research 9410-12 Options:
  • 9410-12 - HV - High Voltage Output (400V L-N range)
Calibration Form NH Research 9410-12

Repair Form NH Research 9410-12
Maximum file size: 40MB

No Related Posts

More Information
Model9410-12

The NH Research 9410-12 Regenerative Grid Simulator delivers 12kW, 24kVA with fully programmable 1, 2, or 3-phase operation. It supports AC voltage from 0–310/400 VRMS L-N, DC output of 200/400V, and frequency range from DC to 100Hz. This advanced 4-quadrant AC source integrates a 125k Sample/sec digitizer for precision waveform capture, plus selectable voltage/current ranges for enhanced accuracy.

Ideal for inverter, UPS, and grid-connected device testing, the NHR 9410-12 offers scalable power modules, regenerative sink capability, and user-defined waveshapes for development, lab, and production environments.

Testwall can supply the used NH Research 9410-12, fully tested. With expert support and global delivery, Testwall ensures high-performance instrumentation with unmatched reliability and service quality. Please contact us directly if you need calibration or repair of the NH Research 9410-12.

Clicky Copyright © 2025-present Magento, Inc. All rights reserved.