Pacific Power 115LSX

| Attribute | Value |
|---|---|
| Output Power | 1500 VA |
| Output Voltage Range | 0–300 VAC |
| Output Frequency Range | 45–500 Hz |
| Number of Output Phases | Single Phase |
| Input Voltage | 115 VAC |
| Input Frequency | 47–63 Hz |
| Waveform | True Sine Wave |
| Total Harmonic Distortion (THD) | Less than 0.5% at full linear load |
| Regulation | ±0.1% load regulation |
| Programming Interface | IEEE-488 (GPIB) and RS-232 |
Pacific Power 115LSX Options:
- 115LSX - T - Transformer Option (Direct/Transformer Coupled Selectable Output, 45 Hz - 1200 Hz, with transformer ratios 1:1.5, 1:2.0, 1:2.5)
- 115LSX - C - Interharmonics Generator Option
- 115LSX - E - Export Version
- 115LSX - LSXM - Reduced Feature Set Economy Version (Sine wave output only, fixed phase angles, no transient programming, no harmonic measurements, no waveform capture, no programmable output impedance)
| Model | 115LSX |
|---|
The Pacific Power 115LSX Power Source delivers low-noise, low-distortion analog power conversion technology for superior voltage quality and peak current capability. Its frequency range of 15Hz–1200Hz supports 400Hz fixed and 360Hz–800Hz wild frequency testing with excellent harmonic performance. Full control of voltage, current, frequency, phase angles, and transients makes it ideal for complex Test Program Sets (TPS) with minimal programming effort.
Equipped with a full-color LCD display and soft key menus, the 115LSX ensures easy operation. Users can generate transients for voltage, waveform, and frequency directly from the front panel with an intuitive spreadsheet-style interface, making it suitable for diverse AC power test applications.
Testwall can supply the used Pacific Power 115LSX, fully tested. With expert support and global delivery, Testwall ensures high-performance instrumentation with unmatched reliability and service quality. Please contact us directly if you need calibration or repair of the Pacific Power 115LSX.