Pacific Power 120LSX

| Attribute | Value |
|---|---|
| Output Power | 120 VA |
| Output Voltage Range | 0–300 VAC |
| Output Frequency Range | 45–500 Hz |
| Number of Phases | Single Phase |
| Waveform | Pure Sine Wave |
| Input Voltage | 120 VAC, 60 Hz |
| Total Harmonic Distortion (THD) | Less than 0.5% at full resistive load |
| Voltage Regulation | ±0.1% of full scale |
| Frequency Resolution | 0.1 Hz |
| Output Voltage Resolution | 0.1 VAC |
Pacific Power 120LSX Options:
- 120LSX - T - Transformer Option (Direct/Transformer Coupled Selectable Output, 45 Hz - 1200 Hz)
- 120LSX - C - Interharmonics Generator Option
- 120LSX - E - Export Version
- 120LSX - LSXM - Reduced Feature Set Economy Version (Sinewave only, no Transient Programming, no Harmonic Measurements, no Waveform Capture, no Programmable Output Impedance)
| Model | 120LSX |
|---|
The Pacific Power 120LSX Power Source features low noise and low distortion analog power conversion for superior voltage quality and high peak current capability. It offers a frequency range of 15Hz to 1200Hz, supporting fixed 400Hz and variable 360Hz–800Hz wild frequency applications with excellent harmonic performance. Full control is provided over voltage, current, frequency, phase angles, and transient conditions, enabling execution of complex Test Program Sets (TPS) with minimal effort.
Equipped with a full-color LCD display and intuitive soft-key menus, the 120LSX simplifies operation and transient creation. Its spreadsheet-style data entry ensures quick setup of voltage, waveform, and frequency outputs. With advanced functionality, it supports AC power compliance, transformer, appliance, DC charger, and UPS testing with unmatched flexibility.
Testwall can supply the used Pacific Power 120LSX, fully tested. With expert support and global delivery, Testwall ensures high-performance instrumentation with unmatched reliability and service quality. Please contact us directly if you need calibration or repair of the Pacific Power 120LSX.