Pacific Power 360-AMX

| Attribute | Value |
|---|---|
| Output Voltage Range | 0 to 300 VAC (single phase), programmable |
| Frequency Range | 45 Hz to 5000 Hz, programmable |
| Output Power Rating | 360 VA continuous |
| Output Current | Up to 3.0 Arms continuous |
| Waveform | Low distortion sine wave output |
| Input Voltage | 105–125 VAC, single phase, 50/60 Hz |
| Voltage Regulation | ±0.1% of full scale |
| Frequency Accuracy | ±0.01% of set frequency |
| Control Interface | Front panel controls with digital display; optional IEEE-488 / RS-232 remote interface |
| Total Harmonic Distortion (THD) | Less than 0.5% at full rated load |
Pacific Power 360-AMX Options:
- 360-AMX - UPC-3M - Three Phase Manual Controller, 15 Hz to 1,200 Hz, Sine waveform only, no remote interface
- 360-AMX - UPC-3 - Three Phase Programmable Controller, 15 Hz to 1,200 Hz, RS-232 Std./GPIB Optional, Sine + 21 Editable waveforms
- 360-AMX - UPC-32 - Three Phase Programmable Controller, 20 Hz to 5,000 Hz, GPIB Std./RS-232 Optional, Sine + 15 Editable waveforms
- 360-AMX - XFMR-1.5:1 - Dual Range Output Transformer, 1.5:1 ratio, extends output voltage to 0-202V (l-n) / 0-350V (l-l), frequency range 45–5,000 Hz
- 360-AMX - XFMR-2.0:1 - Dual Range Output Transformer, 2.0:1 ratio, extends output voltage to 0-270V (l-n) / 0-468V (l-l), frequency range 45–5,000 Hz
- 360-AMX - XFMR-2.5:1 - Dual Range Output Transformer, 2.5:1 ratio, extends output voltage to 0-338V (l-n) / 0-585V (l-l), frequency range 45–5,000 Hz
- 360-AMX - MST - Master/Slave Selectable Paralleling option, delivered with UPC-32 Controller, Master/Slave select switch on rear panel
- 360-AMX - SLV - Dedicated Slave unit for paralleling, requires 360AMX Master of same base model
- 360-AMX - HAS - Waveform Harmonic Analysis and Synthesis option (available with UPC-3 or UPC-32 controller)
- 360-AMX - PROG-Z - Programmable Output Impedance option, compensates for line distribution or transformer losses
- 360-AMX - LINE-SYNC - Line Sync option (available with UPC-3 or UPC-32 controller)
| Model | 360-AMX |
|---|
The Pacific Power Source 360AMX delivers single or two-phase output by converting three-phase line voltage into precise split or single-phase power. It operates across 20–5,000 Hz (direct) and 45–5,000 Hz (transformer coupled) with advanced UPC-32 control. Featuring independent phase control, it ensures low distortion, no switching noise, high peak current capability, and fast slew rates.
Equipped with a micro-controller, the 360AMX functions as an integrated test system. It simulates power conditions and transients while analyzing performance parameters, making it ideal for demanding laboratory and industrial test applications.
Testwall can supply the used Pacific Power 360AMX, fully tested. With expert support and global delivery, Testwall ensures high-performance instrumentation with unmatched reliability and service quality. Please contact us directly if you need calibration or repair of the Pacific Power 360AMX.