Pacific Power Source 3060-MS

| Attribute | Value |
|---|---|
| Output Power | 3000 VA / 3 kVA |
| Output Voltage Range | 0–300 VAC (Single Phase), 0–150/300 VAC (Split Phase) |
| Output Frequency Range | 45–500 Hz |
| Number of Output Phases | 1 Phase / Split Phase |
| Total Harmonic Distortion (THD) | Less than 0.5% at full linear load |
| Input Voltage | 105–125 VAC or 210–250 VAC (Single Phase) |
| Input Frequency | 47–63 Hz |
| Waveform | True Sine Wave |
| Programming & Control Interface | IEEE-488 (GPIB) and RS-232 Serial Interface |
| Operating Temperature | 0°C to 40°C (32°F to 104°F) |
Pacific Power Source 3060-MS Options:
- 3060-MS - /CE - CE Mark. Includes Output Circuit Breaker (/OCB)
- 3060-MS - /CSTB - Casters
- 3060-MS - /OCB - Output Circuit Breaker
- 3060-MS - /M99575 - Split Phase Output Configurations (50 kW)
- 3060-MS - /M99583 - Split Phase Output Configurations (32 kW)
- 3060-MS - /G - GPIB Interface, SCPI Commands & IEEE488.2 (standard)
- 3060-MS - /S - RS232 Interface. SCPI Commands, Baudrate up to 38.4 kBps. (Replaces GPIB, no cost option)
- 3060-MS - UPC-Studio - Windows AC Power Source control Software (no cost option)
- 3060-MS - ABD0100 - License for Avionics Test Sequences according to norm ABD0100.8.1. Requires UPC-Test Manager Option.
- 3060-MS - A350 - License for Avionics Test Sequences according to norm Airbus A350. Requires UPC-Test Manager Option.
- 3060-MS - DO160 - License for Avionics Test Sequences according to norm DO160 Version E. Requires UPC-Test Manager Option.
- 3060-MS - IEC-AC-4XX - IEC 61000-4 AC Immunity Test Sequences. Includes 4-11, 4-14, 4-27, 4-28 and 4-34. Excludes 4-13 Option.
- 3060-MS - SCU/UPC32-413 - IEC 61000-4-13 Inter Harmonic Generator. Required to run 4-13 tests. Includes 4-13 software.
| Model | Source |
|---|
The Pacific Power 3060-MS is a high-power solid-state frequency converter with a 62.5 kVA, 3-phase AC source. It provides precise voltage and frequency conversion through a PWM switchmode inverter and digital oscillator, ensuring maximum reliability and system performance. Input rectification minimizes current distortion and stabilizes power factor for seamless facility integration.
Supporting up to 600V L-L output and 350 Amps of pulse current per phase, the 3060-MS is ideal for transformer testing and nonlinear load applications. It features a variable frequency range of 47–500 Hz and selectable fixed frequencies of 50, 60, or 400 Hz for versatile testing environments.
Testwall can supply the used Pacific Power 3060-MS, fully tested. With expert support and global delivery, Testwall ensures high-performance instrumentation with unmatched reliability and service quality. Please contact us directly if you need calibration or repair of the Pacific Power 3060-MS.