Anritsu MA2421A

| Atrybut | Wartość |
|---|---|
| Zakres częstotliwości | 10 MHz – 18 GHz |
| Zakres mocy | -70 dBm do +20 dBm |
| Typ głowicy pomiarowej | Diodowa głowica pomiarowa mocy |
| Złącze RF | APC-3.5 (SMA) |
| Impedancja wejściowa | 50 Ω |
| Maksymalna moc wejściowa (CW) | +20 dBm (100 mW) |
| Współczynnik SWR | ≤ 1,35 (do 18 GHz) |
| Niepewność kalibracji | ±0,9% (przy 50 MHz) |
| Temperatura pracy | 0°C do +55°C |
| Kompatybilność z miernikami mocy | Anritsu ML2430A, ML2480B i inne modele serii ML |
Anritsu MA2421A Options:
- ML2490A - 06 - Rear Mount Input A
- ML2490A - 07 - Rear Input A and Reference
- ML2490A - 08 - Rear Mount Inputs A, B and Reference
- ML2490A - 09 - Rear Mount Inputs A and B
- ML2490A - 33 - Extra Operating Manual
- ML2490A - 34 - Extra Programming Manual
- ML2490A - 37 - Electronic Manuals (deletes paper version from shipment)
- ML2490A - 98 - Calibration to Z540, ISO Guide 25
- ML2490A - 99 - Premium Calibration
- ML2480A - 06 - Rear Mount Input A
- ML2480A - 07 - Rear Input A and Reference
- ML2480A - 08 - Rear Mount Inputs A, B and Reference
- ML2480A - 09 - Rear Mount Inputs A and B
- ML2480A - 15 - Factory Fitted 50MHz and 1GHz Calibrator (required by MA2411B Sensor)
- ML2480A - 15R - Retro Fit Calibrator Kit
- ML2480A - 33 - Extra Operating Manual ML2487/8A
- ML2480A - 34 - Extra Programming Manual ML2487/8A
- ML2480A - 35 - Extra Operating Manual: Japanese
- ML2480A - 36 - Extra Programming Manual: Japanese
- ML2480A - 37 - Electronic Manuals only (deletes paper version from shipment)
- ML2480A - 98 - Calibration to Z540, ISO Guide 25
- ML2480A - 99 - Premium Calibration
- ML2400A - 32A - Maintenance Manual ML2480/90A Series
- ML2400A - 31A - Option 31, Extra Operation/Prog manual ML2480A
- ML2400A - 06 - Rear Mount Input A on ML2437A
- ML2400A - 07 - Rear Input A and Reference on ML2437A
- ML2400A - 08 - Rear Mount Inputs A, B and Reference
- ML2400A - 09 - Rear Mount Inputs A and B on ML2438A
- ML2400A - 11 - NiMH Battery with Desktop Charger
- ML2400A - 11A - NiMH Battery with Desktop Charger (for use in Japan only)
- ML2400A - 22 - 3m Sensor Cable
- ML2400A - 23 - 5m Sensor Cable
- ML2400A - 24 - 10m Sensor Cable
- ML2400A - 25 - 30m Sensor Cable
- ML2400A - 26 - 50m Sensor Cable
- ML2400A - 27 - 100m Sensor Cable
- ML2400A - 30 - Extra Operation Manual ML2437/8A
- ML2400A - 98 - Calibration to Z540, ISO Guide 25
- ML2400A - 99 - Premium Calibration
- ML2400A - 30A - Option 30, Extra Operation/Prog manual (For use in Japan, only)
- ML2400A - 10585-00003 - Maintenance Manual ML2400A Series
- ML2400A - 33 - Extra Operating & Programming Manual ML2437/8A
- MA2499B - MA2499B - Anritsu 4700 & 4600 Series Sensor Adapter
- ML2400A - 01 - Rack Mount, single unit
- ML2400A - 03 - Rack Mount, side by side
- ML2400A - 05 - Front Bail Handle
- ML2400A - 12 - Front Panel Cover
- ML2400A - 20 - Spare 1.5m Sensor Cable
- ML2400A - 21 - 0.3m Sensor Cable
- ML2400A - 28 - RS232 Bootload Cable
- ML2400A - 29 - Bulkhead Adapter
- MA2418A - MA2418A - 50 MHz Reference Oscillator with Power Supply
- MA2419A - MA2419A - Range Calibrator
- MA2497A - MA2497A - Agilent/HP84xxA Series Sensor Adaptor
- MA2421A - 760-209 - Hardside Transit Case
- MA2421A - D41310 - Soft Carry Case with Shoulder Strap
| Model | MA2421A |
|---|
Anritsu MA2421A to czujnik mocy termicznej oparty na efekcie Seebecka, zapewniający precyzyjny pomiar średniej mocy prawdziwej w paśmie od 100 kHz do 18 GHz, od –30 dBm do +20 dBm, cechuje się wysoką liniowością, stabilnością i niskim współczynnikiem odbicia dzięki dynamicznej kalibracji przez zintegrowane EEPROM.
Idealny do zastosowań RF i mikrofalowych, oferuje szybką odpowiedź narostu/opadu < 4 ms, niezależne od kształtu fali wykrywanie termoparowe i szeroki zakres dynamiczny 50 dB, zapewniając niezawodną pracę w różnych środowiskach testowych.
Testwall może dostarczyć używany Anritsu MA2421A, w pełni przetestowany. Dzięki wsparciu ekspertów i globalnej dostawie Testwall zapewnia instrumenty o wysokiej wydajności oraz niezrównaną niezawodność i jakość obsługi. Skontaktuj się z nami bezpośrednio, jeśli potrzebujesz kalibracji lub naprawy Anritsu MA2421A.