Fluke

Fluke 773

Milliamp Process Clamp Meter
0 mA do 24 mA Zakres pomiaru prądu pętli 4-20 mA
±0,2% + 2 cyfry Dokładność pomiaru prądu
Tak, z krokiem 0,001 mA Symulacja prądu pętli 4-20 mA
4 baterie alkaliczne AA (LR6) Zasilanie
Do 400 godzin pracy Żywotność baterii
Zamów kartę katalogową
Atrybut Wartość
Zakres pomiaru prądu pętli 4-20 mA 0 mA do 24 mA
Dokładność pomiaru prądu ±0,2% + 2 cyfry
Symulacja prądu pętli 4-20 mA Tak, z krokiem 0,001 mA
Zasilanie 4 baterie alkaliczne AA (LR6)
Żywotność baterii Do 400 godzin pracy
Wyświetlacz Cyfrowy wyświetlacz LCD z podświetleniem
Zakres temperatury pracy -10°C do +50°C
Stopień ochrony IP40
Wymiary 193 mm x 92 mm x 46 mm
Masa 430 g (z bateriami)
Formularz kalibracji Fluke 773

Formularz naprawy Fluke 773
Maximum file size: 40MB

No Related Posts

Więcej informacji
Model773

 FLUKE  773 Milliamp Process Clamp Meter

 

The Fluke 773 Milliamp Process Clamp Meter  is a accurate, versatile, and highly portable tool, designed  saves time and money by measuring 4 €“20 mA signals five times faster than with traditional multimeters, and without breaking the loop. That means you can troubleshoot a live device without having to power down and possibly miss something going on in the process.  Fluke 773 Milliamp Process Clamp Meter features the unique mA scale to measure a mA signal without breaking the loop and output that signal to another device to record the measurements.

The Fluke  773 Milliamp Process Clamp Meter is ideal for troubleshooting transmitters, valves, and programmable logic controllers (PLCs) found in process plants. The 773 allows you to connect to a mA loop in a traditional series workflow to measure, source, or simulate a control system. And it measures up to 99.0 mA non-contact, including 10 to 50 mA signals in older control systems.  Fluke 773 Milliamp Process Clamp Meter  also sources and measures DC voltage, so it can be used to troubleshoot voltage input and output devices that accept a 1-5 V or 0 to 10 V signal. You can detach the clamp section of the meter and use it as a remote jaw, connected to the main body by an extension cable to make it easier to take measurements in tight spaces.

 

Specifications for the  FLUKE  773 Milliamp Process Clamp Meter Include:

mA measurement range  (Measured by Clamp) 0 to 20.99 mA,  21.0 to 100.0 mA
Accuracy  (Measured by Clamp) 0.2% + 5 counts,  1 % + 5 counts
Diameter of measurable conductor 0.177" or 4.5 mm max
Operating temperature -10 to 50 ºC

 