Kaelus iPA-0900A

| Attribute | Value |
|---|---|
| Frequency Band | GSM900 |
| Transmit (TX) | TX1 932.5-937.5 MHz, TX2 949-960 MHz |
| Receive (PIM) | 903-915 MHz |
| Output Power | 0.1 to 20 W per tone (+20 to +43 dBm, 1 dB steps), ±0.5 dB |
| IM Orders | 3rd and 5th order, reverse (reflected) |
| Residual PIM | < -117 dBm / -160 dBc max (< -125 dBm / -168 dBc typ.) at 2 x 20 W |
| RF Port | 7-16 DIN female |
| Display / Control | 4.3 in touch screen |
| Battery | 25.9 V Li-ion, removable |
| Environmental | -10 to +45 °C operating; IP54 (IP67 in optional hard case) |
| Dimensions / Weight | 369 x 160 x 240 mm (H x D x W); 12 kg |
Kaelus iPA-0900A Options:
- RTF module - Range to Fault module: distance to PIM and return loss faults (sold separately)
- Dual battery charger - Standalone charger for spare battery packs
- Hard case - Optional hard case giving IP67 protection when enclosed
- iAK-0060A - Portable PIM accessory kit
Kaelus iPA-0900A to zasilany bateryjnie analizator intermodulacji pasywnej (PIM) dla pasma GSM900, o mocy od 0,1 do 20 W na nośną. Przeznaczony jest do pomiarów na szczycie i u podstawy masztu, na dachach oraz w wewnątrzbudynkowych systemach DAS i mierzy wsteczną (odbitą) PIM 3. i 5. rzędu.
Jest to starszy model z serii Kaelus iPA. Tryby pracy obejmują monitor widma, przemiatanie PIM w funkcji częstotliwości oraz rejestrację PIM w funkcji czasu, z generowaniem raportów w urządzeniu i sterowaniem z ekranu dotykowego lub zdalnie przez Wi-Fi. Jest kompatybilny z opcjonalnym modułem Kaelus RTF (Range to Fault) do lokalizacji usterek PIM i strat odbiciowych.
Testwall dostarcza używany Kaelus iPA-0900A, w pełni przetestowany, z 12-miesięczną gwarancją i dostawą na terenie całej Europy. Na życzenie możemy zorganizować kalibrację przed wysyłką. Prosimy o kontakt, jeśli potrzebują Państwo kalibracji lub naprawy urządzenia Kaelus iPA-0900A.