Kaelus

Kaelus iPA-1800A

Battery-portable 20 W PIM analyser, DCS1800 band, 7-16 DIN, Wi-Fi remote control
DCS1800: TX1 1805-1812 MHz, TX2 1825-1880 MHz, RX 1710-1785 MHz Frequency Band
0.1 to 20 W per tone (+20 to +43 dBm, 1 dB steps), ±0.5 dB Output Power
< -117 dBm / -160 dBc max (< -125 dBm / -168 dBc typ.) at 2 x 20 W Residual PIM
3rd and 5th, reverse (reflected) IM Orders
-50 to -128 dBm; noise floor < -128 dBm Measurement Range
Attribute Value
Frequency Band DCS1800: TX1 1805-1812 MHz, TX2 1825-1880 MHz, RX 1710-1785 MHz
Output Power 0.1 to 20 W per tone (+20 to +43 dBm, 1 dB steps), ±0.5 dB
Residual PIM < -117 dBm / -160 dBc max (< -125 dBm / -168 dBc typ.) at 2 x 20 W
IM Orders 3rd and 5th, reverse (reflected)
Measurement Range -50 to -128 dBm; noise floor < -128 dBm
RF Port 7-16 DIN female
Display / Control 4.3 in touch screen; Wi-Fi remote control
Environmental -10 to +45 °C operating; 5-95% RH non-condensing
Dimensions / Weight 369 x 240 x 160 mm; 12 kg
Kaelus iPA-1800A Options:
  • RTF-2000 - Range to Fault module: distance to PIM and return loss faults (sold separately)
  • Dual battery charger - Standalone charger for spare battery packs
  • Hard case - Optional hard case giving IP67 protection when enclosed
  • Tablet case - Ruggedised tablet case for remote control (tablet not included)
Formularz kalibracji Kaelus iPA-1800A

Formularz naprawy Kaelus iPA-1800A
Maximum file size: 40MB

The Kaelus iPA-1800A is a battery-powered, IEC-compliant passive intermodulation (PIM) analyser for the DCS1800 band, rated at 2 x 20 W. It is built for tower-top, tower-base, rooftop and in-building DAS testing, with local touch-screen control or remote control from a Wi-Fi tablet, phone or laptop. It measures reverse (reflected) 3rd and 5th order PIM.

Operating modes include spectrum monitor, PIM-versus-frequency sweep and PIM-versus-time trace, with on-instrument reporting. It is compatible with the optional RTF-2000 Range to Fault module.

Testwall can supply the used Kaelus iPA-1800A, fully tested, with a 12-month warranty and delivery across Europe. Calibration can be arranged on request before shipping. Please contact us if you need calibration or repair of the Kaelus iPA-1800A.