50 MHz – 33 GHz Zakres częstotliwości
-35 dBm do +20 dBm Zakres mocy
2,92 mm (K-type), żeński Typ złącza
±0,9% (przy 50 MHz, 0 dBm, 25°C) Niepewność kalibracji
50 Ω Impedancja

| Atrybut | Wartość |
|---|---|
| Zakres częstotliwości | 50 MHz – 33 GHz |
| Zakres mocy | -35 dBm do +20 dBm |
| Typ złącza | 2,92 mm (K-type), żeński |
| Niepewność kalibracji | ±0,9% (przy 50 MHz, 0 dBm, 25°C) |
| Impedancja | 50 Ω |
| Współczynnik SWR (VSWR) | ≤ 1,15 (do 18 GHz), ≤ 1,35 (do 33 GHz) |
| Maksymalna moc wejściowa (ciągła) | 300 mW (24,8 dBm) |
| Temperatura pracy | 0°C do +55°C |
| Kompatybilne mierniki mocy | Keysight N1911A, N1912A, E4416A, E4417A oraz inne mierniki serii EPM |
| Czas nagrzewania | Około 30 minut dla pełnej specyfikacji |
Keysight (Agilent) N8488A Options:
- N8488A - CFT - SCPI code-compatible to 8480 Series sensors (Note: Option CFT is not available for the N8488A)
- N8488A - 100 - 1.85 mm (male) connector for N8488A
- N8488A - 1A7 - ISO 17025 calibration with test data
- N8488A - A6J - ANSI Z540 calibration with test data
- N8488A - R-51B-001-3C - Return to Keysight Technologies Warranty - 3 years
- N8488A - R-51B-001-5C - Warranty Assurance Plan - Return to Keysight Technologies - 5 years
- N8488A - OB1 - English language Operating and Service Guide
- N8488A - ABJ - Japanese localization Operating and Service Guide
| Model | N8488A |
|---|
KEYSIGHT N8488A
The Keysight N8488A power sensor has the widest frequency range in Keysight's family of N8480 power sensors. Each of these new sensors allow users to calibrate the power sensor without manually entering the calibration factors in to the power meter. Similar to the rest of N8480 power sensors, the new N8488A power sensors are designed with excellent accuracy, linearity, repeatability, and SWR.
Features and Specifications of the Keysight N8488A (Agilent) Power Sensor include:
- EEPROM to store cal factors eliminates manual entry
- Wide frequency range from 10 MHz to 67 GHz (Not warranted spec from 67 to 70 GHz)
- Wide dynamic range from -35 to +20 dBm
- Best-in-class power linearity of less than 1%, excellent SWR of mismatch uncertainty and highly accurate power repeatability
- Accurate calibration and traceability to US National Institute of Standards and Technology (NIST)
- SCPI codes compatibility
- Compatible with EPM (new N1913/14A, E4418/19B), EPM-P (E4416/17A), P-Series (N1911/12A) power meters