Rohde & Schwarz RTO2012 Digital Oscilloscope

| Attribute | Value |
|---|---|
| Bandwidth | 1 GHz |
| Number of Channels | 2 |
| Sample Rate | 5 Gsample/s (10 Gsample/s with interleaving) |
| Memory Depth | 50 Mpoints per channel (100 Mpoints interleaved) |
| Vertical Resolution | 8 bits (up to 16 bits with High Definition mode) |
| Display | 10.4-inch capacitive touchscreen, 1024 x 768 resolution |
| Time Base Range | 25 ps/div to 10,000 s/div |
| Input Impedance | 50 Ω / 1 MΩ selectable |
| Waveform Update Rate | Up to 1,000,000 waveforms/second |
| Connectivity & Interfaces | USB, LAN (LXI), DisplayPort, optional GPIB |
Rohde & Schwarz RTO2012 Digital Oscilloscope Options:
- RTO2012 - RTO-B1 - Mixed Signal Option, 400 MHz (additional 16 logic channels)
- RTO2012 - RTO-B4 - OCXO 10 MHz (precision reference frequency with reference input and output connectors)
- RTO2012 - RTO-B10 - GPIB Interface
- RTO2012 - RTO-B19 - Additional Solid State Disk
- RTO2012 - RTO-B101 - Memory Upgrade, 100 Msample per channel
- RTO2012 - RTO-B102 - Memory Upgrade, 200 Msample per channel
- RTO2012 - RTO-B104 - Memory Upgrade, 400 Msample per channel
- RTO2012 - RTO-B110 - Memory Upgrade, 1 Gsample per channel
- RTO2012 - RTO-B201 - Upgrade of RTO2012 to 1 GHz bandwidth (via RTO-B201)
- RTO2012 - RTO-B212 - Upgrade of RTO2012 to 2 GHz bandwidth
- RTO2012 - RTO-B213 - Upgrade of RTO2012 to 3 GHz bandwidth
- RTO2012 - RTO-K1 - I2C/SPI Serial Decoding
- RTO2012 - RTO-K2 - UART/RS-232/RS-422/RS-485 Serial Decoding
- RTO2012 - RTO-K3 - CAN/LIN Serial Triggering and Decoding
- RTO2012 - RTO-K4 - FlexRay Serial Triggering and Decoding
- RTO2012 - RTO-K5 - I2S Serial Triggering and Decoding
- RTO2012 - RTO-K6 - MIL-STD-1553 Serial Triggering and Decoding
- RTO2012 - RTO-K7 - ARINC 429 Serial Triggering and Decoding
- RTO2012 - RTO-K8 - Ethernet Serial Decoding
- RTO2012 - RTO-K9 - CAN-FD Serial Triggering and Decoding
- RTO2012 - RTO-K10 - SENT Serial Triggering and Decoding
- RTO2012 - RTO-K11 - I/Q Software Interface
- RTO2012 - RTO-K12 - Jitter Analysis
- RTO2012 - RTO-K13 - Clock Data Recovery (CDR)
- RTO2012 - RTO-K17 - High Definition Mode
- RTO2012 - RTO-K19 - Zone Trigger
- RTO2012 - RTO-K21 - USB 2.0 Compliance Test
- RTO2012 - RTO-K22 - Ethernet Compliance Test
- RTO2012 - RTO-K31 - Power Analysis
- RTO2012 - RTO-K40 - MIPI RFFE Serial Triggering and Decoding
- RTO2012 - RTO-K42 - MIPI D-PHY Serial Triggering and Decoding
- RTO2012 - RTO-K50 - Manchester and NRZ Serial Triggering and Decoding
- RTO2012 - RTO-K52 - 8b10b Serial Decoding
- RTO2012 - RTO-K55 - MDIO Serial Triggering and Decoding
- RTO2012 - RTO-K60 - USB 1.0/1.1/2.0/HSIC Serial Triggering and Decoding
- RTO2012 - RTO-K65 - SpaceWire Serial Triggering and Decoding
| Model | RTO2012 |
|---|
The Rohde & Schwarz RTO2012 Digital Oscilloscope features 2 channels with 1GHz bandwidth and 10 Gsample/s sample rate, delivering exceptional signal fidelity and up to 16-bit vertical resolution. Designed for precise multi-domain testing, it integrates time, frequency, logic, and protocol analysis within a compact, user-friendly device.
Equipped with high acquisition rates and SmartGrid technology, the RTO2012 supports efficient signal debugging and dynamic waveform customization through its intuitive touchscreen interface and gesture controls.
Testwall can supply the used Rohde & Schwarz RTO2012, fully tested. With expert support and global delivery, Testwall ensures high-performance instrumentation with unmatched reliability and service quality. Please contact us directly if you need calibration or repair of the Rohde & Schwarz RTO2012.