Schaffner NSG 200E

| Attribute | Value |
|---|---|
| Output Voltage Range | Up to 4 kV peak |
| ESD Test Standards | IEC 61000-4-2, EN 61000-4-2 |
| Discharge Modes | Contact discharge and air discharge |
| Voltage Steps | 10 V increments |
| Polarity | Positive and negative |
| Discharge Counter | Built-in discharge counter with preset function |
| Discharge Tip Types | Includes contact and air discharge tips per IEC 61000-4-2 |
| Power Supply | 9 V battery operated (portable handheld design) |
| Discharge Interval | Adjustable discharge repetition rate |
| Calibration | Factory calibrated; calibration certificate included |
Schaffner NSG 200E Options:
- NSG 200E - 402-227 - Universal safety connectors (set of 3 pieces)
- NSG 200E - 402-251 - Measurement adapter
| Model | NSG 200E |
|---|
The Schaffner NSG 200E Mainframe is designed to house up to six different plug-in generators for precise line interference simulation. It provides essential shared functions such as mains connection, filtering, phase indication, and pulse injection. With a robust table-top housing and optional rack-mounting capability, the unit is adaptable for diverse test environments.
This system supports switchable EUT supply and phase monitoring, making it suitable for advanced compliance testing and simulation of complex interference conditions with high reliability.
Testwall can supply the used Schaffner NSG 200E, fully tested. With expert support and global delivery, Testwall ensures high-performance instrumentation with unmatched reliability and service quality. Please contact us directly if you need calibration or repair of the Schaffner NSG 200E.