Sorensen SGI800-31.2

ManufacturerSorensen
ModelSGI800-31.2
ProductDC Power Supply, 800V, 31.2A, 25kW
TypeUsed

 

Sorensen SGI800-25

Sorensen SGI800-25

Sorensen SGI800-37.5

Sorensen SGI800-37.5

Get Quote
SKU
139260
SORENSEN SGI800-31.2 DC Power Supply (call for availability)The Sorensen SGI800-31.2 DC Power Supply is a high powered, programmable power supply designed for exceptional load transient response, low noise, and the highest power density in the industry. The power density is enhanced by a stylish front air intake allowing supplies to be stacked without any required clearance between unitsThe Sorensen SGI800-31.2 DC Power Supply (SGI = Sorensen General Purpose Intelligent) combines onboard intelligent controls with outstanding power electronics. These controls enable sophisticated sequencing, constant power mode and save/recall of instrument settings. Looping of sequences makes the Sorensen SGI800-31.2 DC Power Supply ideal for repetitive testing. An impressive vacuum fluorescent graphical display in eight languages, context sensitive "soft" keys and front panel keyboard simplify programming of the Sorensen SGI800-31.2 DC Power Supply.Features and Specifications of the Sorensen SGI800-31.2 DC Power Supply include:
  • High Power Density: Up to 30 kW in a 6U chassis
  • Wide Voltage Range: 0-10V up to 0-800V, in increments of 5 kW from 5 to 30 kW
  • Fast Load Transient Response: Protection from undesired voltage excursions
  • Low RMS and P-P Noise:  Suitable for the most sensitive applications
  • Parallelable up to 150 kW: Expandable as your requirement grows
  • Modular Design: Upgradeable for the ultimate in investment protection
  • Sequencing:  Program custom waveforms
  • Easy-to-read Fluorescent Display: SGI supports English, French, German, Italian, Spanish, Chinese, Japanese, and Korean languages
  • 16-bit Resolution:  Optional IEEE-488.2 + RS-232C + Ethernet provides precise control
  • Ethernet Control: LXI Class C compliant communication through integrated web server 
  • Direct Relay Control: Control output and sense isolation relays, along with polarity relays. (Ethernet Option Only)
  • Hardware Trigger: Ethernet Option Only
  • Common:
  • Remote Sense:  Terminals are provided to sense output voltage at point of load. Maximum line drop 5% of rated voltage per line for 40-100V models, line drop 1V of rated voltage per line for 10-20V models, 1.5V for 30V models, 2% of rated voltage per line for models 160V and greater. (Greater line drop is allowed, but output regulation specifications no longer apply).
  • Parallel Operation:  Up to 5 units may be paralleled for additional cur within the power supply single-unit specifications, with exception of the DC output cur set accuracy. Additional paralleled SG units will add 0.3% inaccuracy per unit. To parallel more than 5 units, contact factory.
  • Series Operation:  Up to 2 units
  • Input:
  • Nominal Voltage 3 phase, 3 wire + ground:   
      • 208/220 VAC (operating range 187 - 242 VAC)
      • 380/400 VAC (operating range 342 - 440 VAC)
      • 440/480 VAC (operating range 396 - 528 VAC)
  • Frequency:  47 – 63Hz , 400Hz
  • Power Factor
      • >0.9 typical for 208/220 VAC input (10V - 800V)
      • >0.78 typical for 380/400 VAC input (40V - 800V)
      • >0.9 typical for 380/480 VAC input (10V - 30V)
      • >0.7 typical for 440/480 VAC input (40V - 800V)
      • >0.9 typical for 440/480 VAC input (10V - 30V)
  • Protection:  ½ cycle ride-though on all three phases, 3 cycle ride through on single phase; missing phase shutdown (800V model 6.4 msec on all 3 phases)
    • 208/220 VAC (operating range 187 - 242 VAC)
    • 380/400 VAC (operating range 342 - 440 VAC)
    • 440/480 VAC (operating range 396 - 528 VAC)
  • 208/220 VAC (operating range 187 - 242 VAC)
  • 380/400 VAC (operating range 342 - 440 VAC)
  • 440/480 VAC (operating range 396 - 528 VAC)
    • >0.9 typical for 208/220 VAC input (10V - 800V)
    • >0.78 typical for 380/400 VAC input (40V - 800V)
    • >0.9 typical for 380/480 VAC input (10V - 30V)
    • >0.7 typical for 440/480 VAC input (40V - 800V)
    • >0.9 typical for 440/480 VAC input (10V - 30V)
  • >0.9 typical for 208/220 VAC input (10V - 800V)
  • >0.78 typical for 380/400 VAC input (40V - 800V)
  • >0.9 typical for 380/480 VAC input (10V - 30V)
  • >0.7 typical for 440/480 VAC input (40V - 800V)
  • >0.9 typical for 440/480 VAC input (10V - 30V)
  • Output:
  • Voltage and Cur Range: 800V, 31.2A, 25kW
  • Ripple & Noise:
      • rms(20Hz-300kHz): 80mV
      • p-p: 500mV
    • rms(20Hz-300kHz): 80mV
    • p-p: 500mV
  • rms(20Hz-300kHz): 80mV
  • p-p: 500mV
  • Programming & Read-Back Specifications:
  • Front Panel Display:
    • Programming:
      • Accuracy:
        • (40-800V) +/- 0.1% of voltage at full scale
        • (40-800V) +/- 0.4% of cur at full scale
      • Resolution: 4.0 digits
    • Read-Back Monitoring:
      • Accuracy: 
        • Voltage: +/- 0.1% of full scale
        • Cur: +/- 0.4% of full scale
      • Resolution: 4.0 digits
    • Knob control & Display read-back
  • Remote Analog Interface
    • Programming:
      • Accuracy:
        • Voltage: +/-0.25% of full scale
        • Cur: (40-800V) 0.8% of full scale 
    • Read-Back Monitoring:
      • Accuracy: (40-800V) +/-1.0% of full scale
    • 25-pin D-sub connector (0~5 V or 0~10 V)
  • Remote Digital Interface:
    • Programming:
      • Accuracy:
        • Voltage:  +/- 0.1% of full scale
        • Cur: +/- 0.4% of full scale
      • Resolution: +/-0.002% of full scale
    • Read-Back Monitoring:
      • Accuracy:
        • Voltage:  +/- 0.15% of full scale
        • Cur:  +/- 0.4% of full scale
      • Resolution:  +/-0.002% of full scale
    • RS-232C (Standard on SGI), Optional IEEE-488.2 and Optional LXI Compliant 10/100 base-T Ethernet
  • OVP:
    • Programming:
      • Accuracy: +/- 1% of full scale
      • Resolution: +/-0.002% of full scale
    • Programming range: 5-110% Configured from front panel, remote analog or via optional digital inputs
  • User I/O:
    • Disconnect & Polarity-reversal relay control (Only available with Ethernet Option)
  • Programming:
    • Accuracy:
      • (40-800V) +/- 0.1% of voltage at full scale
      • (40-800V) +/- 0.4% of cur at full scale
    • Resolution: 4.0 digits
  • Read-Back Monitoring:
    • Accuracy: 
      • Voltage: +/- 0.1% of full scale
      • Cur: +/- 0.4% of full scale
    • Resolution: 4.0 digits
  • Knob control & Display read-back
  • Accuracy:
    • (40-800V) +/- 0.1% of voltage at full scale
    • (40-800V) +/- 0.4% of cur at full scale
  • Resolution: 4.0 digits
  • (40-800V) +/- 0.1% of voltage at full scale
  • (40-800V) +/- 0.4% of cur at full scale
  • Accuracy: 
    • Voltage: +/- 0.1% of full scale
    • Cur: +/- 0.4% of full scale
  • Resolution: 4.0 digits
  • Voltage: +/- 0.1% of full scale
  • Cur: +/- 0.4% of full scale
  • Programming:
    • Accuracy:
      • Voltage: +/-0.25% of full scale
      • Cur: (40-800V) 0.8% of full scale 
  • Read-Back Monitoring:
    • Accuracy: (40-800V) +/-1.0% of full scale
  • 25-pin D-sub connector (0~5 V or 0~10 V)
  • Accuracy:
    • Voltage: +/-0.25% of full scale
    • Cur: (40-800V) 0.8% of full scale 
  • Voltage: +/-0.25% of full scale
  • Cur: (40-800V) 0.8% of full scale 
  • Accuracy: (40-800V) +/-1.0% of full scale
  • Programming:
    • Accuracy:
      • Voltage:  +/- 0.1% of full scale
      • Cur: +/- 0.4% of full scale
    • Resolution: +/-0.002% of full scale
  • Read-Back Monitoring:
    • Accuracy:
      • Voltage:  +/- 0.15% of full scale
      • Cur:  +/- 0.4% of full scale
    • Resolution:  +/-0.002% of full scale
  • RS-232C (Standard on SGI), Optional IEEE-488.2 and Optional LXI Compliant 10/100 base-T Ethernet
  • Accuracy:
    • Voltage:  +/- 0.1% of full scale
    • Cur: +/- 0.4% of full scale
  • Resolution: +/-0.002% of full scale
  • Voltage:  +/- 0.1% of full scale
  • Cur: +/- 0.4% of full scale
  • Accuracy:
    • Voltage:  +/- 0.15% of full scale
    • Cur:  +/- 0.4% of full scale
  • Resolution:  +/-0.002% of full scale
  • Voltage:  +/- 0.15% of full scale
  • Cur:  +/- 0.4% of full scale
  • Programming:
    • Accuracy: +/- 1% of full scale
    • Resolution: +/-0.002% of full scale
  • Programming range: 5-110% Configured from front panel, remote analog or via optional digital inputs
  • Accuracy: +/- 1% of full scale
  • Resolution: +/-0.002% of full scale
  • Disconnect & Polarity-reversal relay control (Only available with Ethernet Option)
  •     

    No Related Posts

    Returns

    If you are not completely satisfied with your purchase, simply return the item to us in its original condition within 30 days of receipt.

    Returned items should be unused and must be returned in original packaging with any enclosed documentation. We will issue a full refund on receipt, excluding the original delivery charge. Alternatively, if preferred, we will exchange the item.

    VAT

    Prices exclude VAT. Intra-Community transactions: Under the EU VAT Directive, B2B sales of goods across EU VAT borders is VAT zero-rated.
    Where VAT is charged, a rate of 23% is applied.

    VAT is not charged outside of the EU.

    Clicky