Watts, VA, VAR, Power Factor, Volts RMS, Amps RMS, Frequency, Harmonics Measurement Parameters
Up to 600V RMS Voltage Input Range
Up to 100A RMS (with external shunt or clamp) Current Input Range
DC and 10 Hz to 1 MHz Frequency Range
0.1% of reading Basic Accuracy

| Attribute | Value |
|---|---|
| Measurement Parameters | Watts, VA, VAR, Power Factor, Volts RMS, Amps RMS, Frequency, Harmonics |
| Voltage Input Range | Up to 600V RMS |
| Current Input Range | Up to 100A RMS (with external shunt or clamp) |
| Frequency Range | DC and 10 Hz to 1 MHz |
| Basic Accuracy | 0.1% of reading |
| Display | Large LCD display with simultaneous multi-parameter readout |
| Interface / Connectivity | RS-232 serial interface for PC connectivity and data logging |
| Harmonic Analysis | Up to 50th harmonic measurement and analysis |
| Power Supply | Universal AC input, 90–264V AC, 50/60 Hz |
| Standards Compliance | Meets IEC and EN safety standards for electrical test equipment |
Voltech PM100 Options:
- PM100 - IEEE488 - IEEE488 interface for high-speed control and data capture
- PM100 - RS232 - RS232 I/O and parallel printer interface
- PM100 - CHART - Chart recorder and alarm interface (twelve 0-5V DC outputs, two free relay contacts)
- PM100 - VPASLite - VPASLite Windows software for control and data handling
| Model | PM100 |
|---|
Using the proven technology of the world leading Voltech range, these analyzers allow precision bench-top measurements at the price of a portable meter. By connecting directly to the analyzer's 20A-rated internal shunts, the errors of gain and phase found in external cur transformers and transducers are eliminated. For measurements above 20A and 1000V, a broad range of transformers, shunts and DC-coupled transducers can be accommodated. Ideal for general-purpose measurements of watts, power factor, harmonics as well as volts and amps in the design, development and production of electrical and electronic equipment
Other features and specifications include:
- Basic Accuracy: 0.1%
- Bandwidth: DC to 250kHz
- Direct Inputs 1000Vpk / 20A RMS
- Graphics display of waveforms and harmonic barcharts
- W, V, A, VA, Var, Power factor, Cosf, Vpk, Apk, crest factors and frequency
- Harmonics V, A (incl. phase) and W to the 50th
- Total Harmonic Distortion
- Integrator for W-hr, VA-hr, A-hr, VA-hr, average and target PF
- Easy-to-use menu structure available in diffe languages
- Accepts and scales for external cur and voltage transducers