Yokogawa

Yokogawa AQ6375E

Optical Spectrum Analyzer, up to 2500 nm, +20 dBm to -70 dBm
1200 nm to 2400 nm Wavelength Range
±0.5 nm Wavelength Accuracy
0.05 nm Wavelength Resolution
78 dB or more Dynamic Range
-70 dBm Sensitivity (Normal Mode)
Request datasheet
Attribute Value
Wavelength Range 1200 nm to 2400 nm
Wavelength Accuracy ±0.5 nm
Wavelength Resolution 0.05 nm
Dynamic Range 78 dB or more
Sensitivity (Normal Mode) -70 dBm
Level Accuracy ±0.4 dB
Level Range +20 dBm to -90 dBm
Sweep Speed (Single) 0.5 nm/s to 200 nm/s (wavelength dependent)
Internal Light Source Built-in broadband light source for wavelength calibration
Interface USB, GP-IB, Ethernet (LAN)
Yokogawa AQ6375E Options:
  • AQ6375E - -10 - Standard model
  • AQ6375E - -20 - Extended model
  • AQ6375E - -01 - Limited model
  • AQ6375E - -L1 - Wavelength reference source (built-in light source)
  • AQ6375E - -D - Power cord: UL/CSA standard and PSE compliant, 125 V
  • AQ6375E - -F - Power cord: VDE/Korean standard, 250 V
  • AQ6375E - -R - Power cord: Australian standard, 250 V
  • AQ6375E - -H - Power cord: Chinese standard, 250 V
  • AQ6375E - -Q - Power cord: British standard, 250 V
  • AQ6375E - -N - Power cord: Brazilian standard, 250 V
  • AQ6375E - -T - Power cord: Taiwanese standard, 125 V
  • AQ6375E - -B - Power cord: Indian standard, 250 V
  • AQ6375E - -U - Power cord: IEC Plug Type B, 250 V
Calibration Form Yokogawa AQ6375E

Repair Form Yokogawa AQ6375E
Maximum file size: 40MB

No Related Posts

More Information
ModelAQ6375E

 YOKOGAWA AQ6375E Optical Spectrum Analyzer  

 

The Yokogawa AQ6375E  can quickly measure optical characteristics of devices, such as LD, LED light sources, and optical amplifiers. It also has a touch screen and a zoom feature to make it easier to use.  Due to the diffractive technology used, the monochromator in some circumstances could generate high order diffracted light, which appears at wavelengths equal to the integral multiple of input wavelengths.  By cutting incoming light below 1150 nm with the built-in filter, the AQ6375E  drastically reduces the influence of high order diffracted light on the measurement. Thus, the measured data are always reliable and replicate the real signal under test.

The AQ6375E  covers not only the wavelength span used in communications, but also the 2 µm region which is used for environmental sensing, medical, biology and industrial applications. It can measure optical power from +20dBm down to -70dBm thanks to its high-dynamic and very low noise components and circuits used for photo detection. This enables precise measurements of both high power and low power sources.  The AQ6375E  uses a double-pass monochromator structure to achieve high wavelength resolution (0.05 nm) and wide close-in dynamic range (55 dB). Thus, closely allocated signals and noise can be separately measured.

 

Specifications for the  YOKOGAWA AQ6375E Optical Spectrum Analyzer Include:

Wavelength Range

1200 to 2400 nm Standard

1000 to 2500 nm Extended (optional)

Wavelength accuracy ± 0.5 nm (Full range)
Minimum sampling resolution 0.002 nm
Polarization dependence ±0.1 dB (1550 nm)

 