Ceyear 3672C-S
10MHz - 43.5GHz Network Analyser

| Attribute | Value |
|---|---|
| Frequency Range | 10 MHz to 26.5 GHz |
| Output Power Range | -110 dBm to +20 dBm |
| Frequency Resolution | 0.001 Hz |
| SSB Phase Noise | ≤ -115 dBc/Hz @ 10 GHz, 10 kHz offset |
| Harmonic Suppression | ≤ -30 dBc |
| Non-Harmonic Spurious | ≤ -60 dBc |
| Amplitude Accuracy | ±1.0 dB |
| Modulation Types | AM, FM, ΦM, Pulse Modulation |
| Output Connector | 2.92 mm (K-type) female |
| Interface | USB, LAN (LXI), GPIB |
Ceyear 3672C-S Options:
- 3672C-S - 201 - 2-Port Programmable Step Attenuator: Set two 60dB programmable step attenuators for the source path, and two 35dB programmable step attenuators for the receiver path
- 3672C-S - 400 - 4-Port Measurement: Two-source stimulus four-port VNA configuration
- 3672C-S - 401 - 4-Port Programmable Step Attenuator: Set four 60dB programmable step attenuators for the source path, and four 35dB programmable step attenuators for the receiver path (Option 400 is needed)
- 3672C-S - 402 - Active Inter-modulation Measurement: For inter-modulation signal measurement of amplifier (Option 400 is needed)
- 3672C-S - 006 - English Options: Key, Front Panel, Label, Operation System
- 3672C-S - 008 - Pulse Measurement: For pulse S-parameter measurement
- 3672C-S - S10 - Time Domain Measurement: For time-domain test, can locate and analyze the discontinuous positions in devices, fixtures or cables
- 3672C-S - S80 - Frequency Offset Measurement: For frequency offset measurement; millimeter-wave frequency extension main unit needs this option
- 3672C-S - S82 - Mixer Scalar Measurement: For the scalar parameter measurement of mixers (Option 400 is needed)
- 3672C-S - S83 - Mixer Vector Measurement: For the vector parameter measurement of mixers (Option 400 is needed)
- 3672C-S - S84 - Embedded LO Frequency Converter Measurement: For the measurement of embedded LO frequency converters (Option 400, S82 or S83 are needed)
- 3672C-S - S86 - Gain Compression Two-Dimension Sweep Measurement: For the gain compression two-dimension sweep test of amplifier
| Model | 3672C-S |
|---|
The Ceyear 3672C-S offers high-performance vector network analysis with multiple calibration types including frequency response, single port, response isolation, enhanced response, full dual-port, and E-cal. It supports amplitude-frequency, phase-frequency, and group delay measurements with a wide dynamic range and fast sweep speed. Standard interfaces include USB, LAN, GPIB, and VGA for versatile connectivity.
The 3672C-S features a 12.1-inch high-resolution touch screen, multi-window and multi-channel testing, and multiple display formats such as logarithmic amplitude, linear amplitude, Smith chart, and polar coordinates, ensuring efficient and precise analysis.
Testwall can supply the used Ceyear 3672C-S, fully tested. With expert support and global delivery, Testwall ensures high-performance instrumentation with unmatched reliability and service quality. Please contact us directly if you need calibration or repair of the Ceyear 3672C-S.