Ceyear 4051A

3Hz - 4GHz Spectrum Analyser
100 kHz to 3 GHz Frequency Range
-110 dBm to +13 dBm Output Power Range
0.01 Hz Frequency Resolution
≤ -105 dBc/Hz @ 1 GHz, 20 kHz offset SSB Phase Noise
±0.5 dB (typical) Amplitude Accuracy
Request datasheet
Attribute Value
Frequency Range 100 kHz to 3 GHz
Output Power Range -110 dBm to +13 dBm
Frequency Resolution 0.01 Hz
SSB Phase Noise ≤ -105 dBc/Hz @ 1 GHz, 20 kHz offset
Amplitude Accuracy ±0.5 dB (typical)
Harmonic Suppression ≤ -30 dBc
Modulation Types AM, FM, PM, Pulse Modulation
RF Output Connector N-Type Female, 50 Ω
Reference Frequency Internal 10 MHz reference, external reference input supported
Power Supply AC 100–240 V, 50/60 Hz
Ceyear 4051A Options:
  • 4051A - H03 - IF Output: Output third IF signal, output frequency range is 10MHz ~ 160MHz, step resolution is 1Hz
  • 4051A - H08 - Wide Log Detect Output: To output the logarithm wave-detection signal which can reflect the input signal level characteristics
  • 4051A - H34-04 - Low-Noise Preamplifier (low waveband, up to 4GHz)
  • 4051A - H34-09 - Low-Noise Preamplifier (full waveband, up to 9GHz)
  • 4051A - H34-13 - Low-Noise Preamplifier (full waveband, up to 13GHz)
  • 4051A - H34-18 - Low-Noise Preamplifier (full waveband, up to 18GHz)
  • 4051A - H34-26 - Low-Noise Preamplifier (full waveband, up to 26.5GHz)
  • 4051A - S04 - Phase Noise Measurement: SSB phase noise curves and single-point phase noise measurement
  • 4051A - H97 - Mounting Suit: Handles and accessories for 4051 mounting on standard racks
  • 4051A - H98 - English Options: English panels, user manual, operation interface, and operation system. Power supply: AC 100~240V, 50~60Hz
  • 4051A - H99 - Aluminum Transportation Case: High-strength lightweight aluminum transportation case, with handle and roller, convenient for transportation
Calibration Form Ceyear 4051A

Repair Form Ceyear 4051A
Maximum file size: 40MB

No Related Posts

More Information
Model4051A

The Ceyear 4051A signal/spectrum analyzer delivers outstanding performance in dynamic range, phase noise, amplitude accuracy, and test speed. It supports comprehensive functions including spectrum analysis, power measurement, IQ and transient analysis, pulse parameter testing, audio frequency analysis, analog demodulation, and phase noise measurement, ensuring high-precision and reliable results for critical applications.

With flexible configuration options, the 4051A allows enhanced functionality and integration into complex systems. Its wide range of digital and analog signal interfaces makes it ideal for aviation, aerospace, radar detection, communication, navigation, and electronic countermeasure testing environments.

Testwall can supply the used Ceyear 4051A, fully tested. With expert support and global delivery, Testwall ensures high-performance instrumentation with unmatched reliability and service quality. Please contact us directly if you need calibration or repair of the Ceyear 4051A.

Clicky Copyright © 2025-present Magento, Inc. All rights reserved.