Manufacturer Logo
Keysight (Agilent)

Keysight (Agilent) N8488A

Thermocouple Power Sensor, 10 MHz - 67 GHz, -35 to +20 dBm
100 kHz bis 33 GHz Frequenzbereich
-35 dBm bis +20 dBm Leistungsmessbereich
Durchgangs-Leistungssensor (Diodensensor) Sensortyp
2,4-mm-Koaxialanschluss Anschlusstyp
50 Ohm Impedanz
Datenblatt anfordern
Attribut Wert
Frequenzbereich 100 kHz bis 33 GHz
Leistungsmessbereich -35 dBm bis +20 dBm
Sensortyp Durchgangs-Leistungssensor (Diodensensor)
Anschlusstyp 2,4-mm-Koaxialanschluss
Impedanz 50 Ohm
Maximale Eingangsleistung +23 dBm (200 mW)
Kompatible Leistungsmessgeräte Keysight N1911A, N1912A, E4418B, E4419B
VSWR (typisch) ≤ 1,35 (bei 33 GHz)
Kalibrierfrequenz 50 MHz
Betriebstemperaturbereich 0 °C bis +55 °C
Keysight (Agilent) N8488A Options:
  • N8488A - CFT - SCPI code-compatible to 8480 Series sensors (Note: Option CFT is not available for the N8488A)
  • N8488A - 100 - 1.85 mm (male) connector for N8488A
  • N8488A - 1A7 - ISO 17025 calibration with test data
  • N8488A - A6J - ANSI Z540 calibration with test data
  • N8488A - R-51B-001-3C - Return to Keysight Technologies Warranty - 3 years
  • N8488A - R-51B-001-5C - Warranty Assurance Plan - Return to Keysight Technologies - 5 years
  • N8488A - OB1 - English language Operating and Service Guide
  • N8488A - ABJ - Japanese localization Operating and Service Guide
Kalibrierungsformular Keysight (Agilent) N8488A

Reparaturformular Keysight (Agilent) N8488A
Maximum file size: 40MB

Keine verwandten Beiträge

Weitere Informationen
ModelN8488A

KEYSIGHT N8488A

The Keysight N8488A power sensor has the widest frequency range in Keysight's family of N8480 power sensors. Each of these new sensors allow users to calibrate the power sensor without manually entering the calibration factors in to the power meter. Similar to the rest of N8480 power sensors, the new N8488A power sensors are designed with excellent accuracy, linearity, repeatability, and SWR.

Features and Specifications of the Keysight N8488A (Agilent) Power Sensor include:

  • EEPROM to store cal factors eliminates manual entry
  • Wide frequency range from 10 MHz to 67 GHz (Not warranted spec from 67 to 70 GHz)
  • Wide dynamic range from -35 to +20 dBm
  • Best-in-class power linearity of less than 1%, excellent SWR of mismatch uncertainty and highly accurate power repeatability
  • Accurate calibration and traceability to US National Institute of Standards and Technology (NIST)
  • SCPI codes compatibility
  • Compatible with EPM (new N1913/14A, E4418/19B), EPM-P (E4416/17A), P-Series (N1911/12A) power meters  

 

Clicky Copyright © 2013-present Magento, Inc. All rights reserved.