Dranetz-BMI POWERXPLORER PX5-400

Product Power Quality Analyser, 50/60 and 400 Hz

 

Dranetz-BMI CT-3000

Dranetz-BMI CT-3000

Get Quote
Availability:
In stock
SKU
124527
The Dranetz-BMI PowerXplorer PX5-400 Power Quality Analyser integrates the most advanced feature set available in a power monitoring instrument, with an easy-to-navigate, color graphical user interface. With high-speed sampling and data capture (1 microsecond/channel), this 8-channel workhorse simultaneously captures and characterizes thousands of parameters, using a range of standard and customizable operating modes. The unique measurement capabilities of the PowerXplorer include capture of low-medium-high frequency transients through peak, waveshape, rms duration and adaptive high-speed sampling, as well as power measurements to clearly characterize non-sinusoidal and unbalanced systems.Features and highlights of the Dranetz-BMI PowerXplorer PX5-400 Power Quality Analyser include:
  • Tests at 50/60 and 400Hz
  • Meets MIL Standard 1399 Testing
  • Eight channels, 4 voltage & 4 cur
  • Intuitive color touch screen
  • Light weight – About 4 pounds, 2 kg – with rugged rubber boot
  • AC/DC applications
  • Samples at 256 samples/cycle
  • Independent voltage & cur triggering, cross triggering
  • High-speed sampling and data capture (1 microsecond/channel)
  • Oscilloscope-like high speed transient detection (Dranetz 658-like and BMI-8800 like)
  • Detailed event characterization of RMS variations and transients
  • THD/harmonic spectrum and TID/interharmonics spectrum to the 63rd at 50/60 Hz
  • Captures IEEE 1459 parameters for non-sinusoidal and advanced power systems
  • Remote communications—RS-232, Ethernet or USB
  • Battery or AC mode
  • Built in UPS battery with external charger
  • Expanded memory up to 128 MB
  • Available languages – English, Spanish, French, German, Italian, Swedish, Finnish, Chinese, Japanese, Korean
  • DRAN-VIEW enabled (Windows NT, 98, ME, 2000, XP)
  • Measures flicker according to IEC 61000-4-15
  • Complies with IEEE 1159, IEC 61000-4-30 Class A and EN50160
  • PX5-400 is 400 Hz measurement version
  • PowerXplorer users can select from a multitude of data displays such as phasors, waveforms, meters and harmonic spectrums, as well as recording options that include continuous monitoring or report-by exception, and AC and DC measurements for events lasting from a microsecond to an hour.
  • Measured Parameters:
    • (4) diffeial inputs, 1-600 Vrms, AC/DC, 0.1% rdg + 0.05% FS, 256 samples/cycle, 16 bit ADC
    • (4) inputs with CTs 0.1-6000 Arms CT-dependent, AC/DC, 0.1%rdg + CTs, 256 samples/cycle, 16 bit ADC
    • 1 MHz High Speed Sampling, 14 bit ADC, 1%FS
    • Frequency Range, 10m Hz resolution, 15-20 Hz, 45-65 Hz, or 350-450 Hz
    • Phase Lock Loop - Generator tracking
    • Phase Lock Loop - Standard PQ mode
  • Power Quality Triggers:
    • Cycle-by-cycle analysis
    • 256 samples/cycle; 1/2 cycle RMS steps
    • L-L, L-N, N-G RMS Variations: Sags/swells/interruptions
    • RMS Recordings V&I (32 pre-fault, 10K post-fault cycles)
    • Waveshape Recordings (2/6/2 cycles)
    • Low and Medium Frequent Transients - V&I
    • High Frequency Transients - V&I, 3% FS trigger
    • Harmonics Summary Parameters
    • Cross trigger V & I channels
    • RMS Event Characterization (IEEE or IEC)
    • Transient Event Characterization
  • Distortion/Power/Energy:
    • W, VA, VAR, TPF, DPF, Demand, Energy, etc.
    • IEEE 1459 Parameters of distorted and unbalanced
    • Harmonics/Interharmonics per IEC 1000-4-7
    • THD/Harmonic Spectrum (V,I,W) to 63rd at 50/60Hz; 16th at 400Hz
    • TID /Interharmonic Spectrum (V,I) to 63rd at 50/60Hz; 16th at 400Hz
    • Flicker per IEC 1000-4-15 (Pst,Plt,Sliding Plt)
    • Crest Factor, K Factor, Transformer Derating Factor, Telephone Interference Factor
    • Unbalance (max. rms deviation) & sequencing components
    • 5 User Spec Harmonics or Signaling Frequency
    • Vector/Arithmetic/Coincident Parameters
  • Monitoring/Compliance:
    • MIL-STD-1399 (US DoD)
    • IEEE 1159
    • IEC 61000-4-30 Class A
    • EN50160 Quality of Supply
    • Cur Inrush / Energization
    • Voltage Fault recording
    • Long Term Monitoring
    • Continuous Data Logging w/min/max/avg
  • (4) diffeial inputs, 1-600 Vrms, AC/DC, 0.1% rdg + 0.05% FS, 256 samples/cycle, 16 bit ADC
  • (4) inputs with CTs 0.1-6000 Arms CT-dependent, AC/DC, 0.1%rdg + CTs, 256 samples/cycle, 16 bit ADC
  • 1 MHz High Speed Sampling, 14 bit ADC, 1%FS
  • Frequency Range, 10m Hz resolution, 15-20 Hz, 45-65 Hz, or 350-450 Hz
  • Phase Lock Loop - Generator tracking
  • Phase Lock Loop - Standard PQ mode
  • Cycle-by-cycle analysis
  • 256 samples/cycle; 1/2 cycle RMS steps
  • L-L, L-N, N-G RMS Variations: Sags/swells/interruptions
  • RMS Recordings V&I (32 pre-fault, 10K post-fault cycles)
  • Waveshape Recordings (2/6/2 cycles)
  • Low and Medium Frequent Transients - V&I
  • High Frequency Transients - V&I, 3% FS trigger
  • Harmonics Summary Parameters
  • Cross trigger V & I channels
  • RMS Event Characterization (IEEE or IEC)
  • Transient Event Characterization
  • W, VA, VAR, TPF, DPF, Demand, Energy, etc.
  • IEEE 1459 Parameters of distorted and unbalanced
  • Harmonics/Interharmonics per IEC 1000-4-7
  • THD/Harmonic Spectrum (V,I,W) to 63rd at 50/60Hz; 16th at 400Hz
  • TID /Interharmonic Spectrum (V,I) to 63rd at 50/60Hz; 16th at 400Hz
  • Flicker per IEC 1000-4-15 (Pst,Plt,Sliding Plt)
  • Crest Factor, K Factor, Transformer Derating Factor, Telephone Interference Factor
  • Unbalance (max. rms deviation) & sequencing components
  • 5 User Spec Harmonics or Signaling Frequency
  • Vector/Arithmetic/Coincident Parameters
  • MIL-STD-1399 (US DoD)
  • IEEE 1159
  • IEC 61000-4-30 Class A
  • EN50160 Quality of Supply
  • Cur Inrush / Energization
  • Voltage Fault recording
  • Long Term Monitoring
  • Continuous Data Logging w/min/max/avg
  •     

    Returns

    If you are not completely satisfied with your purchase, simply return the item to us in its original condition within 30 days of receipt.

    Returned items should be unused and must be returned in original packaging with any enclosed documentation. We will issue a full refund on receipt, excluding the original delivery charge. Alternatively, if preferred, we will exchange the item.

    VAT

    Prices exclude VAT. Intra-Community transactions: Under the EU VAT Directive, B2B sales of goods across EU VAT borders is VAT zero-rated.
    Where VAT is charged, a rate of 23% is applied.

    VAT is not charged outside of the EU.

    Clicky