emtest

emtest CCI

Capacitive Coupling Clamp
IEC 61000-4-6, ISO 11452-4 Standards Compliance
150 kHz – 230 MHz Frequency Range
Conducted Continuous Interference (CCI) via current injection clamp Injection Method
Up to 100 W (continuous) Output Power
CW, AM (80% @ 1 kHz), pulse modulation Modulation Types
Request datasheet
Attribute Value
Standards Compliance IEC 61000-4-6, ISO 11452-4
Frequency Range 150 kHz – 230 MHz
Injection Method Conducted Continuous Interference (CCI) via current injection clamp
Output Power Up to 100 W (continuous)
Modulation Types CW, AM (80% @ 1 kHz), pulse modulation
Impedance 50 Ω
Control Interface USB, GPIB, RS-232
Level Accuracy ±2 dB
Operating Temperature 0 °C to +40 °C
Power Supply 100–240 V AC, 50/60 Hz
emtest CCI Options:
  • CCI - CCI PVKIT 1 - Kit for CCI Calibration: includes transducer plate (insulated copper foil with 4 mm connection plug, insulation 1,100 mm x 130 mm, copper foil 1,050 mm x 120 mm), acrylblock support for measuring adapter PVF 50 on 100 mm level, and PVF AD3 adapter (4 mm to coaxial SHF connector)
  • CCI - PVF BKIT 1 - Kit for Burst Impulse Verification: includes PVF 50 (coaxial 50 ohm load resistor for EFT/Burst transient verification), PVF 1000 (coaxial 1,000 ohm load resistor for EFT/Burst transient verification), and PVF AD 1 (adapter to match the 4mm/6mm EUT output to the PVF 50 load resistor)
Calibration Form emtest CCI

Repair Form emtest CCI
Maximum file size: 40MB

No Related Posts

More Information
ModelCCI
emtest CCI Capacitive Coupling ClampThe emtest CCI is used to couple EFT/burst pulses to I/O lines as required in diffe European and international standards for immunity testing. The coupling of the Electrical Fast Transients EFT/burst to signal lines can usually not be achieved by discrete capacitive coupling without interfering with the signal flow. It is often impossible to contact the required circuit (direct), e. g. coaxial or shielded cables. In this case the coupling is realized by the capacitive coupling clamp. The interference simulator can be connected on both sides of the coupling clamp.

Features of the emtest CCI include:
  • Connects directly to emtest NX5 Compact Immunity Tester
  • Construction as per IEC 61000-4-4 Ed.3
  • EFT/Burst testing of signal- and datalines
  • Active coupling length 1m
  • Permissable burst voltage 7 kV
  • For cable diameter up to 40 mm
  • The CCI Capactive Coupling Clamp is identical to the HFK Capacitive Coupling Clamp except that it connects the NX5 without the need for adapters.     